CVE-2023-38076

highpriority · track · 0EPSS 0.004 · 38 %ileDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.44% (38th) EPSS
CVSS 7.8 · high
Is it mine?
29 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · nvd

EPSS · scored 2026-10-27

A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.8
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.17.8highAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · ENISA EU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · productcert@siemens.com DEexploitability 1.8 · impact 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (29)

Products and version ranges known to be affected.

showing 20 of 29
05

advisories (3)

Vendor and ecosystem advisories describing this.

  • SSA-278349SSA-278349: Multiple WRL File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go2023-09-12csaf · siemens_psirtDE

    Siemens JT2Go and Teamcenter Visualization are affected by file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.

  • SSA-478780SSA-478780: Multiple WRL File Parsing Vulnerabilities in Tecnomatix Plant Simulation2023-11-14csaf · siemens_psirtDE

    Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2023-2322Siemens JT2Go: Mehrere SchwachstellenDeutsch2023-09-12csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens JT2Go ausnutzen, um beliebigen Programmcode auszuführen oder einen Denial of Service Zustand herbeizuführen.