CVE-2023-38076
highpriority · track · 0EPSS 0.004 · 38 %ileDEEURUUSEPSS · scored 2026-10-27
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21041)
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedJT2Gosiemens_psirt
Update to V14.3.0.1 or later version
https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html - FixedTeamcenter Visualization V13.3siemens_psirt
Update to V13.3.0.12 or later version
https://support.sw.siemens.com/ - FixedTeamcenter Visualization V14.1siemens_psirt
Update to V14.1.0.11 or later version
https://support.sw.siemens.com/ - FixedTeamcenter Visualization V14.2siemens_psirt
Update to V14.2.0.6 or later version
https://support.sw.siemens.com/ - FixedTeamcenter Visualization V14.3siemens_psirt
Update to V14.3.0.1 or later version
https://support.sw.siemens.com/ - FixedTecnomatix Plant Simulation V2201siemens_psirt
Update to V2201.0010 or later version
https://support.sw.siemens.com/ - FixedTecnomatix Plant Simulation V2302siemens_psirt
Update to V2302.0004 or later version
https://support.sw.siemens.com/ - MitigationTecnomatix Plant Simulation V2201siemens_psirt
Do not open untrusted WRL files from using Tecnomatix Plant Simulation
- MitigationTecnomatix Plant Simulation V2302siemens_psirt
Do not open untrusted WRL files from using Tecnomatix Plant Simulation
- No fix plannedTeamcenter Visualization V14.0siemens_psirt
Currently no fix is planned
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (29)
Products and version ranges known to be affected.
- siemens teamcenter visualization13.3.0 → 13.4.0.12nvdUScpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
- siemens teamcenter visualization14.0 → 14.1.0.11nvdUScpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
- siemens teamcenter visualization14.2 → 14.2.0.6nvdUScpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
- siemens teamcenter visualization14.3 → 14.3.0.1nvdUScpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*
- siemens tecnomatix plant simulation2201.0 → 2201.0010nvdUScpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*
advisories (3)
Vendor and ecosystem advisories describing this.
- SSA-278349SSA-278349: Multiple WRL File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go2023-09-12csaf · siemens_psirtDE
Siemens JT2Go and Teamcenter Visualization are affected by file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.
- SSA-478780SSA-478780: Multiple WRL File Parsing Vulnerabilities in Tecnomatix Plant Simulation2023-11-14csaf · siemens_psirtDE
Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.
- WID-SEC-W-2023-2322Siemens JT2Go: Mehrere SchwachstellenDeutsch2023-09-12csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in Siemens JT2Go ausnutzen, um beliebigen Programmcode auszuführen oder einen Denial of Service Zustand herbeizuführen.
also known as (6)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (7)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2023-38076/cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-278349.pdfVendor Advisorynvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-478780.pdfVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan