CVE-2023-35920
highpriority · track · 30EPSS 0.009 · 58 %ileDEEURUUSEPSS · scored 2026-10-27
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC MV540 H (6GF3540-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV540 S (6GF3540-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 H (6GF3550-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 S (6GF3550-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 U (6GF3560-0LE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 X (6GF3560-0HE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV540 H (6GF3540-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV540 S (6GF3540-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 H (6GF3550-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 S (6GF3550-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 U (6GF3560-0LE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 X (6GF3560-0HE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.9–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (36)
Products and version ranges known to be affected.
advisories (2)
Vendor and ecosystem advisories describing this.
- SSA-561322SSA-561322: Multiple Vulnerabilities in SIMATIC MV500 Devices before V3.3.42023-07-11csaf · siemens_psirtDE
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-194-04Siemens SIMATIC MV500 Devices2023-07-11icsa · cisa_csaf_otUS
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.