CVE-2023-2650
mediumpriority · attend · 52EPSS 0.754 · 100 %ileDEEURUUSEPSS · scored 2026-10-23
Issue summary: Processing some specially crafted ASN.1 object identifiers or data containing them may be very slow. Impact summary: Applications that use OBJ_obj2txt() directly, or use any of the OpenSSL subsystems OCSP, PKCS7/SMIME, CMS, CMP/CRMF or TS with no message size limit may experience notable to very long delays when processing those messages, which may lead to a Denial of Service. An OBJECT IDENTIFIER is composed of a series of numbers - sub-identifiers - most of which have no size limit. OBJ_obj2txt() may be used to translate an ASN.1 OBJECT IDENTIFIER given in DER encoding form (using the OpenSSL type ASN1_OBJECT) to its canonical numeric text form, which are the sub-identifiers of the OBJECT IDENTIFIER in decimal form, separated by periods. When one of the sub-identifiers in the OBJECT IDENTIFIER is very large (these are sizes that are seen as absurdly large, taking up tens or hundreds of KiBs), the translation to a decimal number in text may take a very long time. The time complexity is O(n^2) with 'n' being the size of the sub-identifiers in bytes (*). With OpenSSL 3.0, support to fetch cryptographic algorithms using names / identifiers in string form was introduced. This includes using OBJECT IDENTIFIERs in canonical numeric text form as identifiers for fetching algorithms. Such OBJECT IDENTIFIERs may be received through the ASN.1 structure AlgorithmIdentifier, which is commonly used in multiple protocols to specify what cryptographic algorithm should be used to sign or verify, encrypt or decrypt, or digest passed data. Applications that call OBJ_obj2txt() directly with untrusted data are affected, with any version of OpenSSL. If the use is for the mere purpose of display, the severity is considered low. In OpenSSL 3.0 and newer, this affects the subsystems OCSP, PKCS7/SMIME, CMS, CMP/CRMF or TS. It also impacts anything that processes X.509 certificates, including simple things like verifying its signature. The impact on TLS is relatively low, because all versions of OpenSSL have a 100KiB limit on the peer's certificate chain. Additionally, this only impacts clients, or servers that have explicitly enabled client authentication. In OpenSSL 1.1.1 and 1.0.2, this only affects displaying diverse objects, such as X.509 certificates. This is assumed to not happen in such a way that it would cause a Denial of Service, so these versions are considered not affected by this issue in such a way that it would be cause for concern, and the severity is therefore considered low.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedNZ2MHG-TSNT4cisa_csaf_ot
After logging into NZ2MHG-TSNT8F2 or NZ2MHG-TSNT4 through the web interface, update the firmware to the fixed firmware version file mentioned in the above 1 by the function of [System] -> [System Management] -> [Firmware Upgrade] from Function menu. For the detailed procedures, please refer to "CC-Link IE TSN Industrial Managed Switch User's Manual (SH-082449ENG)".
- FixedNZ2MHG-TSNT8F2cisa_csaf_ot
After logging into NZ2MHG-TSNT8F2 or NZ2MHG-TSNT4 through the web interface, update the firmware to the fixed firmware version file mentioned in the above 1 by the function of [System] -> [System Management] -> [Firmware Upgrade] from Function menu. For the detailed procedures, please refer to "CC-Link IE TSN Industrial Managed Switch User's Manual (SH-082449ENG)".
- FixedAnalytiXcisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities. The latest white papers can be found at "https://iconics.com/About/Security/CERT".
https://iconics.com/about/security/cert - FixedAnalytiXcisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf - FixedGENESIS64cisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities. The latest white papers can be found at "https://iconics.com/About/Security/CERT".
https://iconics.com/about/security/cert - FixedGENESIS64cisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf - FixedHyper Historiancisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities. The latest white papers can be found at "https://iconics.com/About/Security/CERT".
https://iconics.com/about/security/cert - FixedHyper Historiancisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf - FixedICONICS Suitecisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities. The latest white papers can be found at "https://iconics.com/About/Security/CERT".
https://iconics.com/about/security/cert - FixedICONICS Suitecisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf - FixedMobileHMIcisa_csaf_ot
Mitsubishi Electric Iconics Digital Solutions is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information, refer to the Mitsubishi Electric Iconics Digital Solutions whitepaper on security vulnerabilities. The latest white papers can be found at "https://iconics.com/About/Security/CERT".
https://iconics.com/about/security/cert - FixedMobileHMIcisa_csaf_ot
Mitsubishi Electric is releasing fixed version 10.97.3 or later for GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, and MobileHMI. Please download the fixed version from the link "https://iconicsinc.my.site.com/community/s/iconics-software/ICONICS_Software__c/00BQQ000008P51V2AS?ICONICS_Software__c-filterId=Product_Version_10_97_3" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf".
https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2024-004_en.pdf - MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationNZ2MHG-TSNT4cisa_csaf_ot
Contact your local Mitsubishi Electric representative to obtain the fixed firmware version file for CC-Link IE TSN Industrial Managed Switch.
- MitigationNZ2MHG-TSNT8F2cisa_csaf_ot
Contact your local Mitsubishi Electric representative to obtain the fixed firmware version file for CC-Link IE TSN Industrial Managed Switch.
- MitigationAnalytiXcisa_csaf_ot
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and devices behind firewalls and isolating them from untrusted networks and hosts, to minimize the risk of exploiting this vulnerability.
- MitigationGENESIS64cisa_csaf_ot
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and devices behind firewalls and isolating them from untrusted networks and hosts, to minimize the risk of exploiting this vulnerability.
- MitigationHyper Historiancisa_csaf_ot
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and devices behind firewalls and isolating them from untrusted networks and hosts, to minimize the risk of exploiting this vulnerability.
- MitigationICONICS Suitecisa_csaf_ot
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and devices behind firewalls and isolating them from untrusted networks and hosts, to minimize the risk of exploiting this vulnerability.
- MitigationMobileHMIcisa_csaf_ot
For users of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric recommend locating control system networks and devices behind firewalls and isolating them from untrusted networks and hosts, to minimize the risk of exploiting this vulnerability.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–high · 3.7–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (134)
Products and version ranges known to be affected.
advisories (18)
Vendor and ecosystem advisories describing this.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- WID-SEC-W-2023-1323OpenSSL: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-05-30csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2023-1614Tenable Security Nessus Network Monitor: Mehrere SchwachstellenDeutsch2023-06-29csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in Tenable Security Nessus Network Monitor ausnutzen, um beliebigen Code auszuführen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszulösen und Daten zu manipulieren.
- WID-SEC-W-2023-1794Oracle MySQL: Mehrere SchwachstellenDeutsch2023-07-18csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-2674Oracle Fusion Middleware: Mehrere SchwachstellenDeutsch2023-10-17csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Fusion Middleware ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-2690Oracle MySQL: Mehrere SchwachstellenDeutsch2023-10-17csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle MySQL ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-2917Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2023-11-14csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2024-0053Dell BIOS: Mehrere SchwachstellenDeutsch2024-01-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen im Dell BIOS ausnutzen, um vertrauliche Informationen offenzulegen, Dateien zu manipulieren oder einen Denial-of-Service-Zustand auszulösen.
- WID-SEC-W-2024-0064Juniper Produkte: Mehrere SchwachstellenDeutsch2024-01-10csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, lokaler oder physischer Angreifer kann mehrere Schwachstellen in Juniper JUNOS, Juniper JUNOS Evolved, Juniper SRX Series, Juniper EX Series, Juniper QFX Series, Juniper ACX Series, Juniper PTX Series und Juniper MX Series ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen und seine Berechtigungen zu erweitern.
- WID-SEC-W-2024-0120Oracle JD Edwards: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle JD Edwards ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-24-158-03Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch2024-06-06icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could allow an attacker to cause a temporary denial-of service (DoS) condition in the web service on the product.
- ICSA-24-184-03Mitsubishi Electric Iconics Digital Solutions and Mitsubishi Electric Products (Update E)2024-06-27icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in denial-of-service, improper privilege management, or potentially arbitrary code execution.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (55)
External citations — patches, advisories, analysis.
- http://www.openwall.com/lists/oss-security/2023/05/30/1cnnvd
- https://access.redhat.com/security/cve/cve-2023-2650cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-2650/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=423a2bc737a908ad0c77bda470b2b59dc879936bcnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=853c5e56ee0b8650c73140816bb8b91d6163422ccnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=9e209944b35cf82368071f160a744b6178f9b098cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=db779b0e10b047f2585615e0b8f2acdf21f8544acnnvd
- https://lists.debian.org/debian-lts-announce/2023/06/msg00011.htmlcnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan