CVE-2023-26495

highpriority · track · 31EPSS 0.004 · 38 %ileDEEUNLUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.44% (38th) EPSS
CVSS 7.8 · high
Is it mine?
7 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-27

An issue was discovered in Open Design Alliance Drawings SDK before 2024.1. A crafted DWG file can force the SDK to reuse an object that has been freed. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.8
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 1.8 · impact 5.9
v3.07.8highCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondaryexploitability 1.8 · impact 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (7)

Products and version ranges known to be affected.

06

advisories (6)

Vendor and ecosystem advisories describing this.

  • NCSC-2024-0332Kwetsbaarheden verholpen in Siemens productenNL2024-08-13csaf · ncsc_nlNL

    Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.

  • SSA-659443SSA-659443: Local Code Execution Vulnerabilities in COMOS Before V10.52024-08-13csaf · siemens_psirtDE

    COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.

  • SSA-975766SSA-975766: Open Design Alliance Drawings SDK Vulnerability in Solid Edge2023-06-13csaf · siemens_psirtDE

    Solid Edge is affected by a file parsing vulnerability in Drawings SDK from Open Design Alliance. If a user is tricked to open a malicious DWG file with the affected application, an attacker could leverage the vulnerability to crash the application or execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions. Note: - This advisory covers security vulnerabilities recently disclosed by Open Design Alliance [0] [0] https://www.opendesign.com/security-advisories

  • ICSA-23-166-09Siemens Solid Edge2023-06-13icsa · cisa_csaf_otUS

    Solid Edge is affected by a file parsing vulnerability in Drawings SDK from Open Design Alliance. If a user is tricked to open a malicious DWG file with the affected application, an attacker could leverage the vulnerability to crash the application or execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions. Note: - This advisory covers security vulnerabilities recently disclosed by Open Design Alliance [0] [0] https://www.opendesign.com/security-advisories

  • ICSA-23-353-04Open Design Alliance Drawing SDK2023-12-19icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow remote attackers to disclose sensitive information on affected installations of ODA Drawing SDK.

  • ICSA-24-228-08Siemens COMOS2024-08-13icsa · cisa_csaf_otUS

    COMOS before V10.5 is affected by two local code execution vulnerabilities in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

10

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan