CVE-2023-25910
highpriority · track · 35EPSS 0.010 · 63 %ileDEEURUUSEPSS · scored 2026-10-27
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC PCS 7siemens_psirt
Update to V9.1 SP2 UC04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC S7-PMsiemens_psirt
Update to V5.7 SP2 HF1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827552/ - FixedSIMATIC STEP 7 V5siemens_psirt
Update to V5.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109794088/ - FixedSIMATIC PCS 7cisa_csaf_ot
Update to V9.1 SP2 UC04 or later version
https://support.industry.siemens.com/cs/ww/en/view/109812242/ - FixedSIMATIC S7-PMcisa_csaf_ot
Update to V5.7 SP2 HF1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827552/ - FixedSIMATIC STEP 7 V5cisa_csaf_ot
Update to V5.7 or later version
https://support.industry.siemens.com/cs/ww/en/view/109794088/ - MitigationSIMATIC PCS 7siemens_psirt
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- MitigationSIMATIC S7-PMsiemens_psirt
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- MitigationSIMATIC STEP 7 V5siemens_psirt
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- MitigationSIMATIC PCS 7cisa_csaf_ot
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- MitigationSIMATIC S7-PMcisa_csaf_ot
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- MitigationSIMATIC STEP 7 V5cisa_csaf_ot
If multiple Engineering Systems are in use ensure that the user accounts in use are restricted to the minimum required operating rights
- WorkaroundSIMATIC PCS 7siemens_psirt
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
- WorkaroundSIMATIC S7-PMsiemens_psirt
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
- WorkaroundSIMATIC STEP 7 V5siemens_psirt
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
- WorkaroundSIMATIC PCS 7cisa_csaf_ot
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
- WorkaroundSIMATIC S7-PMcisa_csaf_ot
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
- WorkaroundSIMATIC STEP 7 V5cisa_csaf_ot
If only one Engineering System is in use, consider changing to "Single terminal system" mode in the "Configure SIMATIC Workspace/Workstation" application, under the "Workstation Configuration" tab. Restart the computer. More details can be found in the following FAQ: https://support.industry.siemens.com/cs/ww/en/view/109821340/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 8.1–10
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (22)
Products and version ranges known to be affected.
advisories (3)
Vendor and ecosystem advisories describing this.
- SSA-968170SSA-968170: Remote Code Execution Vulnerability in SIMATIC STEP 7 V5.x and Derived Products2023-06-13csaf · siemens_psirtDE
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code in the database management system's server (where STEP 7 or PCS 7 are running). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- WID-SEC-W-2023-1433Siemens SIMATIC S7: Schwachstelle ermöglicht Ausführen von beliebigem Programmcode mit AdministratorrechtenDeutsch2023-06-12csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann eine Schwachstelle in Siemens SIMATIC S7 und Siemens SIMATIC STEP 7 ausnutzen, um beliebigen Programmcode mit Administratorrechten auszuführen.
- ICSA-23-166-08Siemens SIMATIC STEP 7 and Derived Products2023-06-13icsa · cisa_csaf_otUS
SIMATIC STEP 7 and PCS 7 contain a database management system that could allow remote users to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code in the database management system's server (where STEP 7 or PCS 7 are running). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
also known as (5)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (7)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/html/ssa-968170.htmlcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdfcnnvd
- https://cxsecurity.com/cveshow/CVE-2023-25910/cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-968170.htmlenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/html/ssa-968170.htmlnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdfMitigationPatchVendor Advisorynvd