CVE-2023-25727
mediumpriority · track · 22EPSS 0.012 · 67 %ileDEEURUUSEPSS · scored 2026-10-27
In phpMyAdmin before 4.9.11 and 5.x before 5.2.1, an authenticated user can trigger XSS by uploading a crafted .sql file through the drag-and-drop interface.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- Fixedfesto_psirt
FactoryViews (non-Lite): Upgrade to FactoryViews 1.6.0. See the upgrade guide for information on how to upgrade. FactoryViews Lite: Upgrade to FactoryViews 1.7.0. See the upgrade guide for information on how to upgrade.
- FixedMES PCfesto_psirt
Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.
- FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedMES PCcisa_csaf_ot
Festo Didactic has released Factory Control Panel as a replacement for XAMPP on its MES PCs. Contact technical support at services.didactic@festo.com to obtain the current version of Factory Control Panel which includes fixes for these vulnerabilities.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (36)
Products and version ranges known to be affected.
- FactoryViews 1.6.0all versionsfixedfesto_psirtDEcpe:2.3:a:festo:factory_views_software:1.6.0:*:*:*:*:*:*:*
- FactoryViews 1.7.0all versionsfixedfesto_psirtDEcpe:2.3:a:festo:factory_views_software:1.7.0:*:*:*:*:*:*:*
advisories (8)
Vendor and ecosystem advisories describing this.
- FSA-202302Festo: Several vulnerabilities in FactoryViews2023-07-10csaf · festo_psirtDE
FactoryViews bundles many third-party applications which are used in background processes to provide the software's features. From time to time, vulnerabilities in these bundled applications are discovered. These are typically fixed in newer versions of FactoryViews by updating the bundled applications. FactoryViews versions up to and including 1.5.2 contain around 200 such vulnerabilities listed in this advisory.Version 1.6.0 is a security rollup release which includes updates to all bundled applications and fixes these vulnerabilities. At this time, FactoryViews Lite cannot be updated beyond version 1.1. FactoryViews 1.7 unifies the non-Lite and Lite versions and fixes these vulnerabilities for users of FactoryViews Lite.
- FSA-202402Several Vulnerabilities in MES PC (Windows 10)2024-02-27csaf · festo_psirtDE
MES PCs shipped with Windows 10 come pre-installed with XAMPP. XAMPP is a bundle of third-party open-source applications including the Apache HTTP Server, the MariaDB database and more. From time to time, vulnerabilities in these applications are discovered. These are fixed in newer versions of XAMPP by updating the bundled applications. MES PCs shipped with Windows 10 include a copy of XAMPP which contains around 140 such vulnerabilities listed in this advisory. They can be fixed by replacing XAMPP with Festo Didactic's Factory Control Panel application.
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- WID-SEC-W-2023-0301phpMyAdmin: Schwachstelle ermöglicht Cross-Site ScriptingDeutsch2023-02-07csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann eine Schwachstelle in phpMyAdmin ausnutzen, um einen Cross-Site Scripting Angriff durchzuführen.
- GHSA-6hr3-44gx-g6whCross-site Scripting vulnerability in drag-and-drop upload of phpMyAdmin2023-02-13ghsa · osvUS
In phpMyAdmin before 4.9.11 and 5.x before 5.2.1, an authenticated user can trigger Cross-site Scripting (XSS) by uploading a crafted .sql file through the drag-and-drop interface. By disabling the configuration directive `$cfg['enable_drag_drop_import']`, users will be unable to use the drag and drop upload which would protect against the vulnerability.
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- ICSA-26-027-02Festo Didactic SE MES PC2024-02-27icsa · cisa_csaf_otUS
MES PCs shipped with Windows 10 come pre-installed with XAMPP. XAMPP is a bundle of third-party open-source applications including the Apache HTTP Server, the MariaDB database and more. From time to time, vulnerabilities in these applications are discovered. These are fixed in newer versions of XAMPP by updating the bundled applications. MES PCs shipped with Windows 10 include a copy of XAMPP which contains around 140 such vulnerabilities listed in this advisory. They can be fixed by replacing XAMPP with Festo Didactic's Factory Control Panel application.
- BIT-phpmyadmin-2023-257272024-03-06vendor · osvUS
In phpMyAdmin before 4.9.11 and 5.x before 5.2.1, an authenticated user can trigger XSS by uploading a crafted .sql file through the drag-and-drop interface.
also known as (6)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (5)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2023-25727/cnnvd
- https://www.phpmyadmin.net/security/PMASA-2023-1/cnnvd
- https://www.phpmyadmin.net/security/PMASA-2023-1/enisa_euvd
- https://lists.debian.org/debian-lts-announce/2025/04/msg00016.htmlnvd
- https://www.phpmyadmin.net/security/PMASA-2023-1/PatchVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan