CVE-2023-22670

highpriority · track · 31EPSS 0.002 · 12 %ileDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.22% (12th) EPSS
CVSS 7.8 · high
Is it mine?
16 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.8
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 1.8 · impact 5.9
v3.07.8highCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.8highAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondaryexploitability 1.8 · impact 5.9
v3.17.8highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.1highCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (16)

Products and version ranges known to be affected.

06

advisories (5)

Vendor and ecosystem advisories describing this.

  • SSA-137900SSA-137900: Multiple Vulnerabilities in COMOS2023-11-14csaf · siemens_psirtDE

    COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

  • SSA-491245SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge2023-02-14csaf · siemens_psirtDE

    Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-047-01Siemens Solid Edge2023-02-14icsa · cisa_csaf_otUS

    Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-23-320-09Siemens COMOS2023-11-14icsa · cisa_csaf_otUS

    COMOS is affected by multiple vulnerabilities that could allow an attacker to execute arbitrary code or cause denial of service condition, data infiltration or perform access control violations. Siemens has released an update for COMOS and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.

  • ICSA-23-353-04Open Design Alliance Drawing SDK2023-12-19icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow remote attackers to disclose sensitive information on affected installations of ODA Drawing SDK.

07

also known as (8)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

10

references (7)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan