CVE-2023-1380
highpriority · track · 34EPSS 0.162 · 97 %ileDEEUNLRUUSEPSS · scored 2026-10-27
A slab-out-of-bound read problem was found in brcmf_get_assoc_ies in drivers/net/wireless/broadcom/brcm80211/brcmfmac/cfg80211.c in the Linux Kernel. This issue could occur when assoc_info->req_len data is bigger than the size of the buffer, defined as WL_EXTRA_BUF_MAX, leading to a denial of service.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.5–7.1
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (116)
Products and version ranges known to be affected.
advisories (7)
Vendor and ecosystem advisories describing this.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- WID-SEC-W-2023-0637Linux Kernel: Schwachstelle ermöglicht Offenlegung von InformationenDeutsch2023-03-13csaf · cert_bundDE
Ein lokaler Angreifer kann eine Schwachstelle in Linux Kernel ausnutzen, um Informationen offenzulegen.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (40)
External citations — patches, advisories, analysis.
- https://access.redhat.com/security/cve/cve-2023-1380cnnvd
- https://bugzilla.redhat.com/show_bug.cgi?id=2177883cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-1380/cnnvd
- https://lists.debian.org/debian-lts-announce/2023/07/msg00030.htmlcnnvd
- https://lists.debian.org/debian-lts-announce/2023/10/msg00027.htmlcnnvd
- https://lore.kernel.org/linux-wireless/20230309104457.22628-1-jisoo.jang@yonsei.ac.kr/T/#ucnnvd
- https://packetstormsecurity.com/files/173087/Kernel-Live-Patch-Security-Notice-LSN-0095-1.htmlcnnvd
- https://packetstormsecurity.com/files/173757/Kernel-Live-Patch-Security-Notice-LSN-0096-1.htmlcnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan