CVE-2023-0590
mediumpriority · track · 19EPSS 0.002 · 13 %ileDEEUNLRUUSEPSS · scored 2026-10-23
A use-after-free flaw was found in qdisc_graft in net/sched/sch_api.c in the Linux Kernel due to a race problem. This flaw leads to a denial of service issue. If patch ebda44da44f6 ("net: sched: fix race condition in qdisc_graft()") not applied yet, then kernel could be affected.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)siemens_psirt
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSCALANCE XCH328 (6GK5328-4TS01-2EC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM324 (6GK5324-8TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM328 (6GK5328-4TS01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XCM332 (6GK5332-0GA01-2AC2)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3)cisa_csaf_ot
Update to V2.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826613/ - FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Only build and run applications from trusted sources
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.3–7
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (73)
Products and version ranges known to be affected.
advisories (11)
Vendor and ecosystem advisories describing this.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- SSA-806742SSA-806742: Multiple Vulnerabilities in SCALANCE XCM-/XRM-300 before V2.42024-02-13csaf · siemens_psirtDE
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- WID-SEC-W-2023-0322Linux Kernel: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-02-09csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann eine Schwachstelle im Linux Kernel ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1086IBM QRadar SIEM: Mehrere SchwachstellenDeutsch2024-05-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in IBM QRadar SIEM ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, einen Denial-of-Service-Zustand herbeizuführen, vertrauliche Informationen offenzulegen, Dateien zu manipulieren, seine Privilegien zu erweitern, einen Cross-Site-Scripting (XSS)-Angriff durchzuführen oder einen nicht spezifizierten Angriff auszuführen.
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-24-046-11Siemens SCALANCE XCM-/XRM-3002024-02-13icsa · cisa_csaf_otUS
SCALANCE XCM-/XRM-300 before V2.4 is affected by multiple vulnerabilities. Siemens has released an update for SCALANCE X-300 and recommends to update to the latest version.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (27)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2023-0590/cnnvd
- https://git.kernel.org/pub/scm/linux/kernel/git/netdev/net.git/commit/?id=ebda44da44f6f309d302522b049f43d6f829f7aaPatchcnnvd
- https://lore.kernel.org/all/20221018203258.2793282-1-edumazet@google.com/cnnvd
- https://packetstormsecurity.com/files/170967/Ubuntu-Security-Notice-USN-5860-1.htmlcnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0806cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0820cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0995cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.1642cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.