CVE-2023-0464
highpriority · track · 41EPSS 0.040 · 90 %ileexploit · PoCDEEUNLRUUSEPSS · scored 2026-10-21
A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service (DoS) attack on affected systems. Policy processing is disabled by default but can be enabled by passing the `-policy' argument to the command line utilities or by calling the `X509_VERIFY_PARAM_set1_policies()' function.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedBFCClientsiemens_psirt
Update to V2.17 or later version. Contact customer support to obtain the update
- FixedSINEC INSsiemens_psirt
Update to V1.0 SP2 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825710/ - FixedSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedTIM 1531 IRC (6GK7543-1MX00-0XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedST7 ScadaConnect (6NH7997-5DA10-0AA0)siemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - FixedSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSCALANCE XM408-4C (6GK5408-4GP00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (6GK5408-8GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (6GK5416-4GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (6GK5528-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (6GK5552-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - Fixedpython311-pymssql-0:2.3.12-1.1.aarch64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython311-pymssql-0:2.3.12-1.1.ppc64le as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython311-pymssql-0:2.3.12-1.1.s390x as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython311-pymssql-0:2.3.12-1.1.x86_64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython312-pymssql-0:2.3.12-1.1.aarch64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython312-pymssql-0:2.3.12-1.1.ppc64le as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython312-pymssql-0:2.3.12-1.1.s390x as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython312-pymssql-0:2.3.12-1.1.x86_64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython313-pymssql-0:2.3.12-1.1.aarch64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython313-pymssql-0:2.3.12-1.1.ppc64le as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython313-pymssql-0:2.3.12-1.1.s390x as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- Fixedpython313-pymssql-0:2.3.12-1.1.x86_64 as component of openSUSE Tumbleweedsuse_csaf
To install this SUSE Security Update use the SUSE recommended installation methods like YaST online_update or "zypper patch".
- FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSINEC INScisa_csaf_ot
Update to V1.0 SP2 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825710/ - FixedST7 ScadaConnect (6NH7997-5DA10-0AA0)cisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955597/ - FixedSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedTIM 1531 IRC (6GK7543-1MX00-0XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSCALANCE XM408-4C (6GK5408-4GP00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (6GK5408-8GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (6GK5416-4GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (6GK5528-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (6GK5552-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedBFCClientcisa_csaf_ot
Update to V2.17 or later version. Contact customer support to obtain the update
- MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Only build and run applications from trusted sources
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- WorkaroundSINEC INSsiemens_psirt
Restrict access to application webserver for trusted users only
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
- WorkaroundSINEC INScisa_csaf_ot
Restrict access to application webserver for trusted users only
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5.3–7.8
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
exploits (1)
Public proof-of-concept and weaponised exploit code.
affected products (158)
Products and version ranges known to be affected.
advisories (29)
Vendor and ecosystem advisories describing this.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- SSA-028723SSA-028723: Multiple OpenSSL Vulnerabilities in BFCClient Before V2.172025-08-12csaf · siemens_psirtDE
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
- SSA-077170SSA-077170: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 22023-12-12csaf · siemens_psirtDE
SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities. Siemens has released an update for SINEC INS and recommends to update to the latest version.
- SSA-337522SSA-337522: Multiple Vulnerabilities in TIM 1531 IRC before V2.4.82024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-341067SSA-341067: Multiple vulnerabilities in third-party components in ST7 ScadaConnect before V1.12024-06-11csaf · siemens_psirtDE
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-625862SSA-625862: Multiple Vulnerabilities in Third-Party Components in SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.32024-06-11csaf · siemens_psirtDE
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- SSA-879734SSA-879734: Multiple Vulnerabilities in SCALANCE XM-400/XR-500 before V6.6.12024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- WID-SEC-W-2023-0732OpenSSL: Schwachstelle ermöglicht Denial of ServiceDeutsch2023-03-22csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann eine Schwachstelle in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen.
- WID-SEC-W-2023-1130GitLab: Mehrere SchwachstellenDeutsch2023-05-02csaf · cert_bundDE
Ein entfernter, authentisierter Angreifer kann mehrere Schwachstellen in GitLab ausnutzen, um seine Privilegien zu erweitern, Sicherheitsvorkehrungen zu umgehen, einen Cross Site Scripting Angriff durchzuführen und Informationen offenzulegen
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2023-1781Oracle Virtualization: Mehrere SchwachstellenDeutsch2023-07-18csaf · cert_bundDE
Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in Oracle Virtualization ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0053Dell BIOS: Mehrere SchwachstellenDeutsch2024-01-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen im Dell BIOS ausnutzen, um vertrauliche Informationen offenzulegen, Dateien zu manipulieren oder einen Denial-of-Service-Zustand auszulösen.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- openSUSE-SU-2026:10199-1python311-pymssql-2.3.12-1.1 on GA media2026-02-13csaf · suse_csafDE
python311-pymssql-2.3.12-1.1 on GA media
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-23-348-16Siemens SINEC INS2023-12-12icsa · cisa_csaf_otUS
SINEC INS before V1.0 SP2 Update 2 is affected by multiple vulnerabilities. Siemens has released an update for SINEC INS and recommends to update to the latest version.
- ICSA-24-165-04Siemens ST7 ScadaConnect2024-06-11icsa · cisa_csaf_otUS
Siemens has released a new version for ST7 ScadaConnect and recommends to update to the latest version.
- ICSA-24-165-06Siemens TIM 1531 IRC2024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-10Siemens SIMATIC and SIPLUS2024-06-11icsa · cisa_csaf_otUS
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-11Siemens SCALANCE XM-400, XR-5002024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-226-21Siemens BFCClient2025-08-12icsa · cisa_csaf_otUS
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (50)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2023-0464/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2017771e2db3e2b96f89bbe8766c3209f6a99545cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=2dcd4f1e3115f38cefa43e3efbe9b801c27e642ecnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=879f7080d7e141f415c79eaa3a8ac4a3dad0348bcnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=959c59c7a0164117e7f8366466a32bb1f8d77ff1cnnvd
- https://lists.debian.org/debian-lts-announce/2023/06/msg00011.htmlcnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.1928cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.2005cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan