CVE-2023-0217
highpriority · track · 31EPSS 0.018 · 79 %ileDEEURUUSEPSS · scored 2026-10-23
An invalid pointer dereference on read can be triggered when an application tries to check a malformed DSA public key by the EVP_PKEY_public_check() function. This will most likely lead to an application crash. This function can be called on public keys supplied from untrusted sources which could allow an attacker to cause a denial of service attack. The TLS implementation in OpenSSL does not call this function but applications might call the function if there are additional security requirements imposed by standards such as FIPS 140-3.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedPCU400 versions 6.5 K and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 6.6.0 or latest
- FixedPCU400 versions 9.4.1 and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 9.4.2 or latest
- No fix plannedPCULogger versions 1.1.0 and belowcisa_csaf_ot
If the PCULogger program is used, then update to version 1.2.0* when available. This version is compatible with PCU400 9.4.2 and later
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.9–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (273)
Products and version ranges known to be affected.
- Aruba ClearPass Policy Managerall versionscert_bundDEcpe:/a:arubanetworks:clearpass_policy_manager:-
advisories (10)
Vendor and ecosystem advisories describing this.
- SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- WID-SEC-W-2023-0304OpenSSL: Mehrere SchwachstellenDeutsch2023-02-07csaf · cert_bundDE
Ein entfernter, authentisierter oder anonymer Angreifer kann mehrere Schwachstellen in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder Chiffretext über ein Netzwerk wiederherzustellen.
- WID-SEC-W-2023-1424Xerox FreeFlow Print Server für Solaris: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- GHSA-vxrh-cpg7-8vjropenssl-src subject to NULL dereference validating DSA public key2023-02-08ghsa · osvUS
An invalid pointer dereference on read can be triggered when an application tries to check a malformed DSA public key by the `EVP_PKEY_public_check()` function. This will most likely lead to an application crash. This function can be called on public keys supplied from untrusted sources which could allow an attacker to cause a denial of service attack. The TLS implementation in OpenSSL does not call this function but applications might call the function if there are additional security requirements imposed by standards such as FIPS 140-3.
- ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-25-065-01Hitachi Energy PCU4002025-02-25icsa · cisa_csaf_otUS
Hitachi Energy is aware of the multiple vulnerabilities related to various versions of OpenSSL library components used in PCU400 versions listed in this document below for IEC62351-3 secure for IEC104/DNP3 or PCULogger tool. These vulnerabilities if exploited, can cause confidentiality and availability impacts. Refer to the Recommended Immediate Actions for information about the available mitigation/remediation strategies.
- RUSTSEC-2023-0012`NULL` dereference validating DSA public key2023-02-07vendor · osvUS
An invalid pointer dereference on read can be triggered when an application tries to check a malformed DSA public key by the `EVP_PKEY_public_check()` function. This will most likely lead to an application crash. This function can be called on public keys supplied from untrusted sources which could allow an attacker to cause a denial of service attack. The TLS implementation in OpenSSL does not call this function but applications might call the function if there are additional security requirements imposed by standards such as FIPS 140-3.
also known as (6)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (22)
External citations — patches, advisories, analysis.
- https://access.redhat.com/security/cve/cve-2023-0217cnnvd
- https://cxsecurity.com/cveshow/CVE-2023-0217/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=23985bac83fd50c8e29431009302b5442f985096cnnvd
- https://packetstormsecurity.com/files/170921/OpenSSL-Toolkit-3.0.8.htmlcnnvd
- https://security.gentoo.org/glsa/202402-08cnnvd
- https://ubuntu.com/security/notices/USN-5844-1Patchcnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0703cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0732cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.