CVE-2022-46351

mediumpriority · track · 22EPSS 0.002 · 14 %ileDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.23% (14th) EPSS
CVSS 5.5 · medium
Is it mine?
25 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-27

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). Specially crafted PROFINET DCP packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2).

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

6.5
010

base score 0–10 · higher = more severe · hover a vector to decode

v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USexploitability 1.8 · impact 3.6
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondary · ENISA EU
v3.15.5mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:Hsecondaryexploitability 1.8 · impact 3.6
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.15.1mediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (25)

Products and version ranges known to be affected.

showing 20 of 25
06

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-363821SSA-363821: Multiple Vulnerabilities in SCALANCE X-200RNA Switch Devices before V3.2.72022-12-13csaf · siemens_psirtDE

    SCALANCE X-200RNA switch devices before V3.2.7 contain multiple vulnerabilities that could allow an attacker to cause a denial of service condition, to extract sensitive information or to hijack existing sessions. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-22-349-02Siemens SCALANCE X-200RNA Switch Devices2022-12-13icsa · cisa_csaf_otUS

    SCALANCE X-200RNA switch devices before V3.2.7 contain multiple vulnerabilities that could allow an attacker to cause a denial of service condition, to extract sensitive information or to hijack existing sessions. Siemens has released updates for the affected products and recommends to update to the latest versions.

07

also known as (3)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

10

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.