CVE-2022-45788

criticalpriority · track · 39EPSS 0.012 · 67 %ileEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.17% (67th) EPSS
CVSS 9.8 · critical
Is it mine?
84 products
Check your exposure
Who says so?
4 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.5–9.8

v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.07.5highCVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.17.5highAV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.5highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.17.5highCVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:Hsecondary · cybersecurity@se.comexploitability 1.6 · impact 5.9
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: none · Automatable: no · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (84)

Products and version ranges known to be affected.

showing 20 of 84
06

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-23-201-01Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers2023-07-20icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker unauthorized access to components, ability to execute arbitrary code, or ability to execute a denial-of-service.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan