CVE-2022-45093
highpriority · track · 35EPSS 0.012 · 69 %ileDEEUUSEPSS · scored 2026-10-27
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product as well as with access to the SFTP server of the affected product (22/tcp), could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSINEC INSsiemens_psirt
Update to V1.0 SP2 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815432/ - FixedSINEC INScisa_csaf_ot
Update to V1.0 SP2 Update 1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109815432/ - MitigationSINEC INSsiemens_psirt
CVE-2022-45093: Disable the SFTP service of the affected product, if not required
- MitigationSINEC INScisa_csaf_ot
CVE-2022-45093: Disable the SFTP service of the affected product, if not required
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (6)
Products and version ranges known to be affected.
advisories (2)
Vendor and ecosystem advisories describing this.
- SSA-332410SSA-332410: Multiple Vulnerabilities in SINEC INS before V1.0 SP2 Update 12023-01-10csaf · siemens_psirtDE
Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components. Siemens has released an update for SINEC INS and recommends to update to the latest version.
- ICSA-23-017-03Siemens SINEC INS2023-01-10icsa · cisa_csaf_otUS
Siemens has released a new version for SINEC INS that fixes multiple vulnerabilities that could allow an attacker to read and write arbitrary files from the file system of the affected component and to ultimately execute arbitrary code on the device. In addition, this version also contains fixes for multiple vulnerabilities in underlying third party components. Siemens has released an update for SINEC INS and recommends to update to the latest version.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan