CVE-2022-4450
highpriority · track · 40EPSS 0.286 · 98 %ileDEEUNLRUUSEPSS · scored 2026-10-23
The function PEM_read_bio_ex() reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case PEM_read_bio_ex() will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial of service attack. The functions PEM_read_bio() and PEM_read() are simple wrappers around PEM_read_bio_ex() and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including PEM_X509_INFO_read_bio_ex() and SSL_CTX_use_serverinfo_file() which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if PEM_read_bio_ex() returns a failure code. These locations include the PEM_read_bio_TYPE() functions as well as the decoders introduced in OpenSSL 3.0. The OpenSSL asn1parse command line application is also impacted by this issue.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedTIM 1531 IRC (6GK7543-1MX00-0XE0)siemens_psirt
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedTeleControl Server Basic V3siemens_psirt
Update to V3.1.2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955177/ - FixedSIMATIC MV540 H (6GF3540-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV540 S (6GF3540-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 H (6GF3550-0GE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 S (6GF3550-0CD10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 U (6GF3560-0LE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 X (6GF3560-0HE10)siemens_psirt
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)siemens_psirt
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)siemens_psirt
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSCALANCE XM408-4C (6GK5408-4GP00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (6GK5408-8GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (6GK5416-4GS00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (6GK5528-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (6GK5552-0AA00-2AR2)siemens_psirt
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSINEC NMSsiemens_psirt
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
Update to V8.10.0.9 or later version The update is available upon request from customer support
- FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSIMATIC MV540 H (6GF3540-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV540 S (6GF3540-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 H (6GF3550-0GE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV550 S (6GF3550-0CD10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 U (6GF3560-0LE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedSIMATIC MV560 X (6GF3560-0HE10)cisa_csaf_ot
Update to V3.3.4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109821128/ - FixedLumada APM Edgecisa_csaf_ot
Hitachi Energy has fixed the vulnerabilities for Lumada APM in version 6.5.0.2 and later and recommends users update their systems to the appropriate version. Lumada APM Edge versions 4.0 and prior are no longer supported and are considered End-of-Life.
- FixedCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2cisa_csaf_ot
Update CC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2 and NZ2MHG-TSNT4 to firmware version 06 or later
- FixedSCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB208 (PN) (6GK5208-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XB216 (PN) (6GK5216-0BA00-2AB2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP (6GK5206-2BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208 (6GK5208-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208EEC (6GK5208-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (6GK5208-0GA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G EEC (6GK5208-0GA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC208G PoE (6GK5208-0RA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216 (6GK5216-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C (6GK5216-4BS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (6GK5216-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC216EEC (6GK5216-0BA00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224 (6GK5224-0BA00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (6GK5224-4GS00-2AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 (6GK5204-0BA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204 DNA (6GK5204-0BA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA (6GK5204-2AA00-2GF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (6GK5208-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208EEC (6GK5208-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (6GK5216-0HA00-2AS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216EEC (6GK5216-0HA00-2ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XP216POE EEC (6GK5216-0UA00-5ES6)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2)cisa_csaf_ot
Update to V4.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109825818/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedFX5-OPCcisa_csaf_ot
FX5-OPC: Use within a LAN and block access from untrusted networks and hosts through firewalls. Restrict physical access to the product, as well as to computers and network devices located within the same network as the product. Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required. Use the IP filter function to block access from untrusted hosts. For details on the IP filter function, please refer to the MELSEC iQ-F FX5 OPC UA Module User's Manual section 4.4 "IP Filter." Do not import untrusted certificates.
- FixedSINEC NMScisa_csaf_ot
Update to V2.0 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109826954/ - FixedSIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedTIM 1531 IRC (6GK7543-1MX00-0XE0)cisa_csaf_ot
Update to V2.4.8 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954889/ - FixedSIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0)cisa_csaf_ot
Update to V2.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109954475/ - FixedSCALANCE XM408-4C (6GK5408-4GP00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (6GK5408-8GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (6GK5416-4GS00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (6GK5528-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedSCALANCE XR552-12M (6GK5552-0AA00-2AR2)cisa_csaf_ot
Update to V6.6.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109955252/ - FixedAFR677cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- FixedAFS650cisa_csaf_ot
AFS650: Update to AFS 650 firmware version 9.1.10
- FixedAFS660-Ccisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- FixedAFS665-Bcisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- FixedAFS670cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- FixedAFS670-V2cisa_csaf_ot
AFS660-C, AFS665-B, AFS670-V2: Update to AFS 66x firmware version 7.1.08
- FixedAFS675cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- FixedAFS677cisa_csaf_ot
AFS670/675/677, AFR677: Update to AFS/AFR 67x firmware version 9.1.10
- FixedSCALANCE WAB762-1 (6GK5762-1AJ00-6AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 (6GK5762-1AJ00-1AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109977720/ - FixedPCU400 versions 6.5 K and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 6.6.0 or latest
- FixedPCU400 versions 9.4.1 and belowcisa_csaf_ot
If IEC62351-3 secure for IEC104/DNP3 is used, then update to version 9.4.2 or latest
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
CVE-2022-4450: Do not import or configure certificate files in PEM format from untrusted sources
- MitigationICONICS Suite including GENESIS64, Hyper Historian, AnalytiX, and MobileHMIcisa_csaf_ot
Additional information about the security updates may also be found in Mitsubishi Electric's security advisories:
- MitigationLumada APM Edgecisa_csaf_ot
Hitachi Energy reported that Lumada APM Edge relies on the HAProxy service (a pre-requisite component) as an API gateway, so it must be exposed to the end-users via network. For Lumada APM Edge to be accessible to the end-users, it is crucial for this service, which also utilizes OpenSSL libraries, to be updated along with its underlying operating system.
- MitigationCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT4cisa_csaf_ot
Additionally, Mitsubishi Electric recommends that customers take the following mitigations to minimize the risk of exploitation of these vulnerabilities:
- MitigationCC-Link IE TSN Industrial Managed Switch NZ2MHG-TSNT8F2cisa_csaf_ot
Additionally, Mitsubishi Electric recommends that customers take the following mitigations to minimize the risk of exploitation of these vulnerabilities:
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Do not import or configure certificate files in PEM format from untrusted sources
- MitigationFX5-OPCcisa_csaf_ot
Mitsbuishi Electric recommends that users update their products to the following versions:
- MitigationGT SoftGOT2000cisa_csaf_ot
GT SoftGOT2000 and OPC UA Data Collector: Do not load untrusted certificate revocation lists (CRLs).
- MitigationMX OPC Server UA (Software packaged with MC Works64)cisa_csaf_ot
MX OPC Server UA: Use recommended mitigations/workarounds
- MitigationOPC UA Data Collectorcisa_csaf_ot
GT SoftGOT2000 and OPC UA Data Collector: Do not load untrusted certificate revocation lists (CRLs).
- MitigationOPC UA Server Unitcisa_csaf_ot
Mitsbuishi Electric recommends that users update their products to the following versions:
- MitigationAFR677cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS650cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS660-Ccisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS665-Bcisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS670cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS670-V2cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS675cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- MitigationAFS677cisa_csaf_ot
Hitachi Energy has released the following mitigations/fixes:
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
- No fix plannedPCULogger versions 1.1.0 and belowcisa_csaf_ot
If the PCULogger program is used, then update to version 1.2.0* when available. This version is compatible with PCU400 9.4.2 and later
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5.9–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (138)
Products and version ranges known to be affected.
advisories (38)
Vendor and ecosystem advisories describing this.
- NCSC-2024-0246Kwetsbaarheden verholpen in Siemens productenNL2024-06-11csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten, zoals SCALANCE, SICAM, Tecnomatix, SITOP en PowerSys.
- NCSC-2025-0061Kwetsbaarheden verholpen in Siemens productenNL2025-02-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten als APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC en Teamcenter.
- SSA-203374SSA-203374: Multiple OpenSSL Vulnerabilities in SCALANCE W1750D Devices2023-03-14csaf · siemens_psirtDE
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-337522SSA-337522: Multiple Vulnerabilities in TIM 1531 IRC before V2.4.82024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- SSA-556635SSA-556635: Multiple Vulnerabilities in Telecontrol Server Basic before V3.1.2.02024-04-09csaf · siemens_psirtDE
Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities.
- SSA-561322SSA-561322: Multiple Vulnerabilities in SIMATIC MV500 Devices before V3.3.42023-07-11csaf · siemens_psirtDE
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-625862SSA-625862: Multiple Vulnerabilities in Third-Party Components in SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.32024-06-11csaf · siemens_psirtDE
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-699386SSA-699386: Multiple Vulnerabilities in SCALANCE XB-200 / XC-200 / XP-200 / XF-200BA / XR-300WG Family before V4.52023-11-14csaf · siemens_psirtDE
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- SSA-769027SSA-769027: Multiple Vulnerabilities fixed in SCALANCE W700 IEEE 802.11ax devices before V3.0.02025-02-11csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- SSA-879734SSA-879734: Multiple Vulnerabilities in SCALANCE XM-400/XR-500 before V6.6.12024-06-11csaf · siemens_psirtDE
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- SSA-943925SSA-943925: Multiple Vulnerabilities in SINEC NMS before V2.0 SP12024-02-13csaf · siemens_psirtDE
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- WID-SEC-W-2023-0304OpenSSL: Mehrere SchwachstellenDeutsch2023-02-07csaf · cert_bundDE
Ein entfernter, authentisierter oder anonymer Angreifer kann mehrere Schwachstellen in OpenSSL ausnutzen, um einen Denial of Service Angriff durchzuführen, Informationen offenzulegen oder Chiffretext über ein Netzwerk wiederherzustellen.
- WID-SEC-W-2023-1424Xerox FreeFlow Print Server für Solaris: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2023-1812Oracle Communications: Mehrere SchwachstellenDeutsch2023-07-18csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Communications ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0114Oracle Systems: Mehrere SchwachstellenDeutsch2024-01-16csaf · cert_bundDE
Ein entfernter, anonymer oder authentisierter Angreifer kann mehrere Schwachstellen in Oracle Systems ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- GHSA-v5w6-wcm8-jm4qopenssl-src contains Double free after calling `PEM_read_bio_ex`2023-02-08ghsa · osvUS
The function `PEM_read_bio_ex()` reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case `PEM_read_bio_ex()` will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial of service attack. The functions `PEM_read_bio()` and `PEM_read()` are simple wrappers around `PEM_read_bio_ex()` and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including `PEM_X509_INFO_read_bio_ex()` and `SSL_CTX_use_serverinfo_file()` which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if `PEM_read_bio_ex()` returns a failure code. These locations include the `PEM_read_bio_TYPE()` functions as well as the decoders introduced in OpenSSL 3.0.
- ICSA-23-075-04Siemens SCALANCE W1750D Devices2023-03-14icsa · cisa_csaf_otUS
The SCALANCE W1750D device contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, decrypt RSA-encrypted messages or create a denial of service condition. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-23-194-04Siemens SIMATIC MV500 Devices2023-07-11icsa · cisa_csaf_otUS
SIMATIC MV500 devices before V3.3.4 are affected by multiple vulnerabilities in the web server and several third-party components. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-229-01ICONICS and Mitsubishi Electric Products2023-08-17icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in information disclosure, denial-of-service, or remote code execution.
- ICSA-23-255-01Hitachi Energy Lumada APM Edge2023-09-12icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclosure of sensitive information.
- ICSA-23-278-03Mitsubishi Electric CC-Link IE TSN Industrial Managed Switch (Update A)2023-10-05icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could result in disclosure of information stored in the product by sending specially crafted packets or could cause a denial-of service (DoS) condition by getting a legitimate user to import a specially crafted certificate.
- ICSA-23-320-08Siemens SCALANCE Family Products2023-11-14icsa · cisa_csaf_otUS
SCALANCE XB-200/XC-200/XP-200/XF-200BA/XR-300WG Family before V4.5 is affected by multiple vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-24-004-02Mitsubishi Electric Factory Automation Products2024-01-04icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could disclose information in the product or could cause denial-of-service (DoS) condition.
- ICSA-24-046-15Siemens SINEC NMS2024-02-13icsa · cisa_csaf_otUS
SINEC NMS before V2.0 SP1 is affected by multiple vulnerabilities. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
- ICSA-24-165-06Siemens TIM 1531 IRC2024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-10Siemens SIMATIC and SIPLUS2024-06-11icsa · cisa_csaf_otUS
SIMATIC CP 1542SP-1 and CP 1543SP-1 before V2.3 are affected by multiple vulnerabilities in third-party components and the integrated web server. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-165-11Siemens SCALANCE XM-400, XR-5002024-06-11icsa · cisa_csaf_otUS
Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-24-205-02Hitachi Energy AFS/AFR Series Products2024-07-23icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition.
- ICSA-25-044-09Siemens SCALANCE W700 IEEE 802.11ax2025-02-11icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11ax family devices are affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions.
- ICSA-25-065-01Hitachi Energy PCU4002025-02-25icsa · cisa_csaf_otUS
Hitachi Energy is aware of the multiple vulnerabilities related to various versions of OpenSSL library components used in PCU400 versions listed in this document below for IEC62351-3 secure for IEC104/DNP3 or PCULogger tool. These vulnerabilities if exploited, can cause confidentiality and availability impacts. Refer to the Recommended Immediate Actions for information about the available mitigation/remediation strategies.
- RUSTSEC-2023-0010Double free after calling `PEM_read_bio_ex`2023-02-07vendor · osvUS
The function `PEM_read_bio_ex()` reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case `PEM_read_bio_ex()` will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial of service attack. The functions `PEM_read_bio()` and `PEM_read()` are simple wrappers around `PEM_read_bio_ex()` and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including `PEM_X509_INFO_read_bio_ex()` and `SSL_CTX_use_serverinfo_file()` which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if `PEM_read_bio_ex()` returns a failure code. These locations include the `PEM_read_bio_TYPE()` functions as well as the decoders introduced in OpenSSL 3.0.
also known as (6)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (57)
External citations — patches, advisories, analysis.
- https://access.redhat.com/security/cve/cve-2022-4450cnnvd
- https://cxsecurity.com/cveshow/CVE-2022-4450/cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=63bcf189be73a9cc1264059bed6f57974be74a83cnnvd
- https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=bbcf509bd046b34cca19c766bbddc31683d0858bcnnvd
- https://packetstormsecurity.com/files/170921/OpenSSL-Toolkit-3.0.8.htmlcnnvd
- https://security.gentoo.org/glsa/202402-08cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0703cnnvd
- https://www.auscert.org.au/bulletins/ESB-2023.0732cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.