CVE-2022-3564
highpriority · track · 39EPSS 0.015 · 73 %ileexploit · PoCCHDEEURUUSEPSS · scored 2026-10-26
A vulnerability classified as critical was found in Linux Kernel. Affected by this vulnerability is the function l2cap_reassemble_sdu of the file net/bluetooth/l2cap_core.c of the component Bluetooth. The manipulation leads to use after free. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-211087.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - FixedSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Update to V1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827684/ - MitigationARM600abb_psirt
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationSWabb_psirt
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationSIMATIC S7-1500 TM MFP - GNU/Linux subsystemsiemens_psirt
Only build and run applications from trusted sources
- MitigationARM600cisa_csaf_ot
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- MitigationSWcisa_csaf_ot
Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. The following mitigations are recommended. 1. Obtain a cellular private access point (APN). A dedicated private cellular access point and respective SIM card subscriptions can be requested from your cellular service provider. This service doesn’t expose the traffic between remote sites and main site to the internet but rather uses cellular operator’s private wide area network (WAN). Therefore, the ARM600 wouldn’t need open ports to the internet. 2. Avoid exposing any system component to the internet. If, however, the ARM600 is exposed to the internet, only the VPN port should be opened towards the internet (e.g., Patrol management connections can be configured to use VPN tunnel and remote administration connections can be implemented by using OpenVPN PC-client). 4. Perform firewall configuration by the "allowlisting" principle, i.e., explicitly allowing only the required ports and protocols and blocking any other traffic. 6. If the internet is used as a WAN media for carrying VPN tunnels, use Demilitarized Zone (DMZ) for terminating connections from the internet (i.e., the remote connections should terminate to the DMZ network, which would be segregated from other networks by a firewall. The ARM600 server would be located into this DMZ). 7. Change the default user credentials of ARM600 and Arctic wireless gateways into non-defaults and use complex non-guessable passwords with special characters. Do not reuse passwords within the system. 8. Use administrator (i.e., root user) privileges only when required by the task. 9. Supporting systems, such as PCs used for configuration, should be frequently updated. If possible, use dedicated site PCs for upgrading and engineering purposes. At minimum, PCs should be investigated by running a full virus scan with recently updated signature files before introducing the PC to the OT system. Any data, such as device configurations and firmware update files transferred to the Arctic system should be virus scanned prior to transferring. 10. Introduce a backup policy, which will ensure periodical backups and backup revision numbering. Consider the following: a. Check that the entire system has backups available from all applicable parts. b. Store the backups in a safe place (e.g. in an encrypted storage), restricted by role-based access control mechanisms. c. Ensure the security of the configuration PCs that may have local copies of device configurations. d. Validate the backups to make sure that they’re working. 11. Follow cyber security best practices for installation, operation, and decommissioning as described in the product’s Cyber Security Deployment Guideline and User Manual. 12. Use continuous monitoring (e.g., intrusion detection/prevention tools) to detect anomalies in the system 13. Consider hardening the system according to the following: a. Remove any unnecessary communication links in the system. b. If possible, close unused physical ports. c. Open only the necessary TCP/UDP ports in the configuration. d. Remove all unnecessary user accounts. e. Restrict traffic by firewall. f. Allow the traffic only from/to necessary hosts' IP addresses (i.e., define both source and destination in the firewall rules, where possible). g. Define client IP address as allowed address in SCADA communication protocols, if such configuration is supported. h. Remove or deactivate all unused processes, communication ports and services, where possible. i. Use physical access controls to the system installations (e.g., to server rooms and device cabinets).
- WorkaroundSIMATIC S7-1500 TM MFP - GNU/Linux subsystemcisa_csaf_ot
Only build and run applications from trusted sources
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5.5–8
weaknesses
The CWE weakness classes this flaw belongs to.
exploits (1)
Public proof-of-concept and weaponised exploit code.
- Trinadh465/linux-4.1.15_CVE-2022-3564Trinadh465/linux-4.1.15_CVE-2022-3564PoC · poc_in_github
affected products (50)
Products and version ranges known to be affected.
advisories (10)
Vendor and ecosystem advisories describing this.
- 2NGA002579ABB Arctic communication solution ARM600 Vulnerabilities2025-04-07csaf · abb_psirtCH
ABB is aware of public reports of a vulnerabilities in product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could cause the product to stop, make the product inacces-sible, take remote control of the product or insert and run arbitrary code. As part of ABB product lifecycle policy, once a product transitions to end-of-life, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document, such as using a private APN cellular network between Arctic wireless gateways and ARM600 for establishing VPN tunnels, to mitigate security risks and avoid potential vulnerabilities. As part of ABB product lifecycle policy, once a product transitions to Limited state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document to mitigate security risks.
- SSA-794697SSA-794697: Vulnerabilities in the Additional GNU/Linux Subsystem of the SIMATIC S7-1500 TM MFP Before V1.12023-06-13csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. SIMATIC S7-1500 TM MFP V1.0 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 (https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- WID-SEC-W-2022-1761Linux Kernel: Mehrere SchwachstellenDeutsch2022-10-17csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen im Linux Kernel ausnutzen, um einen Denial of Service Angriff durchzuführen und einen nicht spezifizierten Angriff auszuführen.
- WID-SEC-W-2023-1432Siemens SIMATIC S7: Mehrere SchwachstellenDeutsch2023-06-12csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, physischer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SIMATIC S7 ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien zu erweitern und Daten zu manipulieren.
- WID-SEC-W-2023-2625IBM QRadar SIEM: Mehrere SchwachstellenDeutsch2023-10-10csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in IBM QRadar SIEM ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen und einen Cross-Site-Scripting-Angriff durchzuführen.
- WID-SEC-W-2024-0064Juniper Produkte: Mehrere SchwachstellenDeutsch2024-01-10csaf · cert_bundDE
Ein Angreifer aus dem angrenzenden Netzwerk oder ein entfernter, anonymer, authentisierter, lokaler oder physischer Angreifer kann mehrere Schwachstellen in Juniper JUNOS, Juniper JUNOS Evolved, Juniper SRX Series, Juniper EX Series, Juniper QFX Series, Juniper ACX Series, Juniper PTX Series und Juniper MX Series ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen und seine Berechtigungen zu erweitern.
- WID-SEC-W-2024-0794Dell ECS: Mehrere SchwachstellenDeutsch2024-04-04csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell ECS ausnutzen, um seine Privilegien zu erweitern, beliebigen Programmcode mit Administratorrechten auszuführen, Informationen offenzulegen, Dateien zu manipulieren, einen Cross-Site-Scripting-Angriff durchzuführen, Sicherheitsvorkehrungen zu umgehen oder einen Denial of Service Zustand herbeizuführen.
- WID-SEC-W-2024-1591Juniper JUNOS: Mehrere SchwachstellenDeutsch2024-07-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Juniper JUNOS ausnutzen, um einen Denial of Service zu verursachen, Informationen offenzulegen, Privilegien zu erweitern und Sicherheitsmechanismen inklusive zu umgehen.
- ICSA-23-166-11Siemens SIMATIC S7-1500 TM MFP Linux Kernel2023-06-13icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.0. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. This advisory lists vulnerabilities for firmware version V1.0 only; for V1.1 refer to Siemens Security Advisory SSA-265688 ( https://cert-portal.siemens.com/productcert/html/ssa-265688.html).
- ICSA-25-105-08ABB M2M Gateway2025-04-07icsa · cisa_csaf_otUS
ABB is aware of public reports of a vulnerabilities in product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could cause the product to stop, make the product inacces-sible, take remote control of the product or insert and run arbitrary code. As part of ABB product lifecycle policy, once a product transitions to end-of-life, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document, such as using a private APN cellular network between Arctic wireless gateways and ARM600 for establishing VPN tunnels, to mitigate security risks and avoid potential vulnerabilities. As part of ABB product lifecycle policy, once a product transitions to Limited state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing mitigations defined in this document to mitigate security risks.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (43)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2022-3564/cnnvd
- https://git.kernel.org/pub/scm/linux/kernel/git/bluetooth/bluetooth-next.git/commit/?id=89f9f3cb86b1c63badaf392a83dd661d56cc50b1cnnvd
- https://lists.debian.org/debian-lts-announce/2022/12/msg00031.htmlcnnvd
- https://lists.debian.org/debian-lts-announce/2022/12/msg00034.htmlcnnvd
- https://packetstormsecurity.com/files/170081/Ubuntu-Security-Notice-USN-5757-2.htmlcnnvd
- https://packetstormsecurity.com/files/170091/Ubuntu-Security-Notice-USN-5756-2.htmlcnnvd
- https://packetstormsecurity.com/files/170238/Ubuntu-Security-Notice-USN-5779-1.htmlcnnvd
- https://packetstormsecurity.com/files/170380/Ubuntu-Security-Notice-USN-5789-1.htmlcnnvd