A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (All versions < V13.2.20220624). The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.6
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 5–9.6

v2.05mediumAV:N/AC:L/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 3.6
v3.19.6criticalCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.19.6criticalCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (10)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-944952SSA-944952: Authentication Bypass Vulnerability in Opcenter Quality2022-07-12csaf · siemens_psirtDE

    Siemens has released updates for Opcenter Quality to fix an authentication bypass vulnerability. This could allow unauthenticated access to the application or cause denial of service condition for existing users. The issue is based on rich client modules using IbsGailWrapper-interface. After issuing the record the authentication bypass vulnerability could take place on all modules. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-22-195-17Siemens Opcenter Quality2022-07-12icsa · cisa_csaf_otUS

    Siemens has released updates for Opcenter Quality to fix an authentication bypass vulnerability. This could allow unauthenticated access to the application or cause denial of service condition for existing users. The issue is based on rich client modules using IbsGailWrapper-interface. After issuing the record the authentication bypass vulnerability could take place on all modules. Siemens has released updates for the affected products and recommends to update to the latest versions.