A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users' sessions.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

8.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6–8

v2.06mediumAV:N/AC:M/Au:S/C:P/I:P/A:Pprimary · NVD / NIST USexploitability 6.8 · impact 6.4
v3.18highCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 2.1 · impact 5.9
v3.18highCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.18highCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.17.3highCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (30)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-348662SSA-348662: Multiple Vulnerabilities in SIMATIC MV500 Devices before V3.32022-07-12csaf · siemens_psirtDE

    SIMATIC MV500 devices before V3.3 are affected by multiple vulnerabilities that could allow attackers to hijack other users' web based management sessions (CVE-2022-33137) or access data on the device without prior authentication (CVE-2022-33138). Siemens has released an update for the SIMATIC MV500 devices and recommends to update to the latest version. Note that the update also contains additional fixes for vulnerabilities documented in Siemens Security Advisory SSA-712929.

  • ICSA-22-195-03Siemens SIMATIC MV500 Devices2022-07-12icsa · cisa_csaf_otUS

    SIMATIC MV500 devices before V3.3 are affected by multiple vulnerabilities that could allow attackers to hijack other users' web based management sessions (CVE-2022-33137) or access data on the device without prior authentication (CVE-2022-33138). Siemens has released an update for the SIMATIC MV500 devices and recommends to update to the latest version. Note that the update also contains additional fixes for vulnerabilities documented in Siemens Security Advisory SSA-712929.