CVE-2022-30115
mediumpriority · track · 17OT risk · elevatedEPSS 0.014 · 72 %ileDEEURUUSEPSS · scored 2026-10-27
Using its HSTS support, curl can be instructed to use HTTPS directly insteadof using an insecure clear-text HTTP step even when HTTP is provided in theURL. This mechanism could be bypassed if the host name in the given URL used atrailing dot while not using one when it built the HSTS cache. Or the otherway around - by having the trailing dot in the HSTS cache and *not* using thetrailing dot in the URL.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - Fixedphoenix_contact_psirt
Update to the latest LTS Firmware Release.Update to the latest LTS PLCnext Engineer Release.Please check Phoenix Contact PSIRT webpage for further Updates of this Advisory.
- FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - Mitigationphoenix_contact_psirt
Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:Measures to protect network-capable devices with Ethernet connection
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (65)
Products and version ranges known to be affected.
- Xerox FreeFlow Print Server v7 for Solarisall versionscert_bundDEcpe:/a:xerox:freeflow_print_server:v7_for_solaris
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
advisories (8)
Vendor and ecosystem advisories describing this.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- VDE-2022-046PHOENIX CONTACT: Multiple Linux component vulnerabilities in PLCnext Firmware2022-11-10csaf · phoenix_contact_psirtDE
UPDATE A: Two devices (ENERGY AXC PU, SMARTRTU AXC SG) added (24.11.2022) Update for PLCnext Firmware containing fixes for recent vulnerability findings in Linux components and security enhancements. PLCnext Control AXC F x152 is certified according to IEC 62443-4-1 and IEC 62443-4-2. This certification requires that all third-party components used in the firmware are regularly checked for known vulnerabilities.
- WID-SEC-W-2022-0277cURL: Mehrere SchwachstellenDeutsch2022-05-10csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in cURL ausnutzen, um Informationen offenzulegen, Sicherheitsvorkehrungen zu umgehen, Dateien zu löschen oder einen Denial of Service zu verursachen.
- WID-SEC-W-2023-1350Splunk Splunk Enterprise: Mehrere Schwachstellen in Komponenten von DrittanbieternDeutsch2023-06-01csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Splunk Splunk Enterprise in diversen Komponenten von Drittanbietern ausnutzen, um einen nicht näher spezifizierten Angriff durchzuführen.
- WID-SEC-W-2023-2031Xerox FreeFlow Print Server: Mehrere SchwachstellenDeutsch2023-08-09csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Xerox FreeFlow Print Server ausnutzen, um die Vertraulichkeit, Verfügbarkeit und Integrität des Systems zu gefährden.
- WID-SEC-W-2023-2229Splunk Splunk Enterprise: Mehrere SchwachstellenDeutsch2023-08-30csaf · cert_bundDE
Ein entfernter, authentifizierter Angreifer kann mehrere Schwachstellen in Splunk Splunk Enterprise ausnutzen, um beliebigen Code auszuführen, einen 'Denial of Service'-Zustand zu verursachen, seine Privilegien zu erweitern und weitere, nicht spezifizierte Auswirkungen zu verursachen.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- CURL-CVE-2022-30115HSTS bypass via trailing dot2022-05-11vendor · osvUS
curl's HSTS check could be bypassed to trick it to keep using HTTP. Using its HSTS support, curl can be instructed to use HTTPS directly instead of using an insecure clear-text HTTP step even when HTTP is provided in the URL. This mechanism could be bypassed if the hostname in the given URL used a trailing dot while not using one when it built the HSTS cache. Or the other way around - by having the trailing dot in the HSTS cache and *not* using the trailing dot in the URL. Since trailing dots in hostnames are somewhat special, many sites work equally fine with or without a trailing dot present.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (24)
External citations — patches, advisories, analysis.
- http://www.openwall.com/lists/oss-security/2022/10/26/4cnnvd
- http://www.openwall.com/lists/oss-security/2022/12/21/1cnnvd
- https://access.redhat.com/security/cve/cve-2022-30115cnnvd
- https://curl.se/docs/CVE-2022-30115.htmlPatchcnnvd
- https://cxsecurity.com/cveshow/CVE-2022-30115/cnnvd
- https://hackerone.com/reports/1557449cnnvd
- https://security.gentoo.org/glsa/202212-01cnnvd
- https://security.netapp.com/advisory/ntap-20220609-0009/cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan