CVE-2022-23450

highpriority · attend · 52EPSS 0.357 · 98 %ileDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
—
no known exploitation
Likely / severe?
35.7% (98th) EPSS
CVSS 10 · high
Is it mine?
14 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

10.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 9–10

v2.010highAV:N/AC:L/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 10 · impact 10
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.110criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.110criticalAV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.110criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (14)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-655554SSA-655554: Multiple Vulnerabilities in SIMATIC Energy Manager before V7.3 Update 12022-04-12csaf · siemens_psirtDE

    SIMATIC Energy Manager is affected by multiple vulnerabilities that could allow an attacker to gain local privilege escalation, local code execution or remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-22-104-11Siemens SIMATIC Energy Manager2022-04-12icsa · cisa_csaf_otUS

    SIMATIC Energy Manager is affected by multiple vulnerabilities that could allow an attacker to gain local privilege escalation, local code execution or remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (7)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan