CVE-2022-23102

mediumpriority · track · 26EPSS 0.047 · 92 %ileDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
4.72% (92nd) EPSS
CVSS 5.8 · medium
Is it mine?
6 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

6.1
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.05.8mediumAV:N/AC:M/Au:N/C:P/I:P/A:Nprimary · NVD / NIST USexploitability 8.6 · impact 4.9
v3.16.1mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nprimary · NVD / NIST USexploitability 2.8 · impact 2.7
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.16.1mediumAV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:Nsecondary · FSTEC (BDU) RU
v3.15.4mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:Fsecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (6)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-654775SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server2022-02-08csaf · siemens_psirtDE

    An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link. Siemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.

  • ICSA-22-041-04Siemens SINEMA Remote Connect Server2022-02-08icsa · cisa_csaf_otUS

    An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link. Siemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.