CVE-2022-2302

highpriority · track · 40EPSS 0.021 · 82 %ileDEEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
2.14% (82nd) EPSS
CVSS 9.3 · high
Is it mine?
15 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · lenze_psirt

EPSS · scored 2026-10-27

Multiple Lenze products of the cabinet series skip the password verification upon second login. After a user has been logged on to the device once, a remote attacker can get full access without knowledge of the password.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • Fixedlenze_psirt

    Install version V01.08.01.3021, which solves the identified security vulnerability.

  • Mitigationlenze_psirt

    As part of a security strategy, Lenze SE recommends the following general defense measures to reduce the risk of exploits: • Only use the products in a protected and controlled environment to minimize network impact and to ensure that they are inaccessible from outside. • Use external firewalls to protect the automation system network and to separate it from other networks. Remark: One Measure should be to block port 4840 via the external firewall and open this port for authenticated access only. • Use Virtual Private Networks (VPN) tunnels when remote access is required. • Use IDS (Intrusion Detection Systems) where possible to detect anomalies in the network. • Activate and use user administration and password functions. • Use encrypted communication links. • Restrict access to both the development tools and their projects and the products of the automation system by physical means, operating system functions, etc. • Protect the development tool by using the latest virus detection solutions. • Use of certificate-based communication via the message security modes Sign or Sign&Encrypt and trust of the corresponding client certificates on the machine controller by the OPC-UA server. This can reduce the risk of exploiting this vulnerability.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 9–9.8

v2.09.3highAV:N/AC:M/Au:N/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 8.6 · impact 10
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · info@cert.vde.comexploitability 3.9 · impact 5.9
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · Lenze PSIRT DE
v3.19criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (15)

Products and version ranges known to be affected.

05

advisories (1)

Vendor and ecosystem advisories describing this.

  • VDE-2022-030Lenze: Vulnerability in the OPC-UA authentification connection in the firmware2022-07-11csaf · lenze_psirtDE

    The machine controller of the cabinet series include an OPC-UA server which uses an user management to authenticate clients via anonymous or user/password authentication. If the user/password authentication is selected, password verification is skipped upon second login. As a result, cases occur in which users can establish communication without correct authentication. This vulnerability is not located in the OPC-UA protocol or server, but in the interface to the products firmware. This Security Advisory is only relevant for the following use cases: • the user management has been activated on the machine controller (is deactivated by default) • the OPC-UA Server is used • Data are transferred via a symbol configuration (is not available by default)

06

also known as (5)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (4)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan