CVE-2021-45033

highpriority · track · 35OT risk · elevatedEPSS 0.009 · 60 %ileDEEUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
0.91% (60th) EPSS
CVSS 8.5 · high
Is it mine?
24 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-24

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.9
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 8.1–9.9

v2.08.5highAV:N/AC:M/Au:S/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 6.8 · impact 10
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 2.8 · impact 5.9
v3.19.9criticalCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.19.9criticalCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.18.1highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (24)

Products and version ranges known to be affected.

showing 20 of 24
05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-324998SSA-324998: Multiple Vulnerabilities in SICAM A80002022-01-11csaf · siemens_psirtDE

    SICAM A8000 devices are impacted by two vulnerabilities. The first one could allow a privileged user to enable a debug port with default credentials. The second vulnerability could allow unauthenticated access to certain previously created log files. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-22-013-02Siemens SICAM A80002022-01-11icsa · cisa_csaf_otUS

    SICAM A8000 devices are impacted by two vulnerabilities. The first one could allow a privileged user to enable a debug port with default credentials. The second vulnerability could allow unauthenticated access to certain previously created log files. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

also known as (3)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (6)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan