A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC PCS 7 V8.2siemens_psirt
Update to V8.2 SP1; then update SIMATIC WinCC to V7.4 SP1 Update 19 or later version to fix CVE-2021-40358 and CVE-2021-40364
https://support.industry.siemens.com/cs/ww/en/view/109806846/ - FixedSIMATIC PCS 7 V9.0siemens_psirt
Update to V9.0 SP3 UC04 or later version to fix CVE-2021-40358 and CVE-2021-40364
https://support.industry.siemens.com/cs/ww/en/view/109780528/ - FixedSIMATIC PCS 7 V9.1siemens_psirt
Update to V9.1 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805073/ - FixedSIMATIC WinCC V15 and earliersiemens_psirt
Update to V15 SP1 Update 7 or later version
https://support.industry.siemens.com/cs/us/en/view/109763890/ - FixedSIMATIC WinCC V16siemens_psirt
Update to V16 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776017/ - FixedSIMATIC WinCC V17siemens_psirt
Update to V17 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - FixedSIMATIC WinCC V7.4siemens_psirt
Update to V7.4 SP1 Update 19 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806846/ - FixedSIMATIC WinCC V7.5siemens_psirt
Update to V7.5 SP2 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793460/ - FixedSIMATIC PCS 7 V8.2cisa_csaf_ot
Update to V8.2 SP1; then update SIMATIC WinCC to V7.4 SP1 Update 19 or later version to fix CVE-2021-40358 and CVE-2021-40364
https://support.industry.siemens.com/cs/ww/en/view/109806846/ - FixedSIMATIC PCS 7 V9.0cisa_csaf_ot
Update to V9.0 SP3 UC04 or later version to fix CVE-2021-40358 and CVE-2021-40364
https://support.industry.siemens.com/cs/ww/en/view/109780528/ - FixedSIMATIC PCS 7 V9.1cisa_csaf_ot
Update to V9.1 SP1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805073/ - FixedSIMATIC WinCC V15 and earliercisa_csaf_ot
Update to V15 SP1 Update 7 or later version
https://support.industry.siemens.com/cs/us/en/view/109763890/ - FixedSIMATIC WinCC V16cisa_csaf_ot
Update to V16 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776017/ - FixedSIMATIC WinCC V17cisa_csaf_ot
Update to V17 Update 2 or later version
https://support.industry.siemens.com/cs/ww/en/view/109784441/ - FixedSIMATIC WinCC V7.4cisa_csaf_ot
Update to V7.4 SP1 Update 19 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806846/ - FixedSIMATIC WinCC V7.5cisa_csaf_ot
Update to V7.5 SP2 Update 5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109793460/ - MitigationSIMATIC PCS 7 V8.2siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V9.0siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V9.1siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V15 and earliersiemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V16siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V17siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V7.4siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V7.5siemens_psirt
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V8.2cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V9.0cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC PCS 7 V9.1cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V15 and earliercisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V16cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V17cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V7.4cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
- MitigationSIMATIC WinCC V7.5cisa_csaf_ot
CVE-2021-40364: Harden the application’s host to prevent local access by untrusted personnel
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 1.8–5.5
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (40)
Products and version ranges known to be affected.
advisories (2)
Vendor and ecosystem advisories describing this.
- SSA-840188SSA-840188: Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products2021-11-09csaf · siemens_psirtDE
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. Note: The vulnerability CVE-2021-40359 is part of a shared component, used by various Siemens products (SIMATIC Communication Services - SCS). The installation of a fix version of any product also removes the vulnerability for other products on the same system, even if those products were not updated.
- ICSA-21-315-03Siemens SIMATIC WinCC (Update E)2021-11-09icsa · cisa_csaf_otUS
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. Note: The vulnerability CVE-2021-40359 is part of a shared component, used by various Siemens products (SIMATIC Communication Services - SCS). The installation of a fix version of any product also removes the vulnerability for other products on the same system, even if those products were not updated.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (6)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdfcnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-315-03cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-multiple-vulnerabilities-via-WinCC-36835cnnvd
- https://www.auscert.org.au/bulletins/ESB-2021.3874cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdfVendor Advisorynvd