CVE-2021-37735

mediumpriority · track · 21EPSS 0.013 · 70 %ileDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.29% (70th) EPSS
CVSS 5 · medium
Is it mine?
10 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-26

A remote denial of service vulnerability was discovered in Aruba Instant version(s): Aruba Instant 6.5.x.x: 6.5.4.18 and below; Aruba Instant 8.5.x.x: 8.5.0.10 and below; Aruba Instant 8.6.x.x: 8.6.0.4 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

5.3
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.05mediumAV:N/AC:L/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.15.3mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Lprimary · NVD / NIST USexploitability 3.9 · impact 1.4
v3.14.9mediumCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.14.9mediumCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.14.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (10)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-917476SSA-917476: Multiple Vulnerabilities in SCALANCE W1750D2021-11-09csaf · siemens_psirtDE

    The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to execute code on the affected device(s), read arbitrary files, or create a denial-of-service condition. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-21-315-06Siemens SCALANCE W1750D2021-11-09icsa · cisa_csaf_otUS

    The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to execute code on the affected device(s), read arbitrary files, or create a denial-of-service condition. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

also known as (3)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (10)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan