CVE-2021-37190

lowpriority · track · 17EPSS 0.004 · 30 %ileDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.36% (30th) EPSS
CVSS 3.3 · low
Is it mine?
6 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-28

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve VPN connection for a known user.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

4.3
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 3.3–4.3

v2.03.3lowAV:A/AC:L/Au:N/C:P/I:N/A:Nprimary · NVD / NIST USexploitability 6.5 · impact 2.9
v3.14.3mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nprimary · NVD / NIST USexploitability 2.8 · impact 1.4
v3.14.3mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.14.3mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondary · ENISA EU
v3.14.3mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:Nsecondaryexploitability 2.8 · impact 1.4
v3.14.3mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.14mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (6)

Products and version ranges known to be affected.

06

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-334944SSA-334944: Vulnerability in SINEMA Remote Connect Server2021-09-14csaf · siemens_psirtDE

    Multiple vulnerabilities in SINEMA Remote Connect Server could allow an unauthorized remote attacker to retrieve or manipulate sensitive information from the affected software. In addition, the attacker could also cause a Denial-of-Service condition in devices controlled by the affected software. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.

  • ICSA-21-257-19Siemens SINEMA Remote Connect Server2021-09-14icsa · cisa_csaf_otUS

    Multiple vulnerabilities in SINEMA Remote Connect Server could allow an unauthorized remote attacker to retrieve or manipulate sensitive information from the affected software. In addition, the attacker could also cause a Denial-of-Service condition in devices controlled by the affected software. Siemens has released an update for the SINEMA Remote Connect Server and recommends to update to the latest version.