CVE-2021-37172

mediumpriority · track · 30EPSS 0.009 · 60 %ileDEEUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.92% (60th) EPSS
CVSS 5 · medium
Is it mine?
6 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · cisa_csaf_ot · nvd

EPSS · scored 2026-10-27

A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

8.1
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5–8.1

v2.05mediumAV:N/AC:L/Au:N/C:N/I:P/A:Nprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:Nprimary · NVD / NIST USexploitability 3.9 · impact 3.6
v3.18.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.18.1highCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (6)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-830194SSA-830194: Missing Authentication Vulnerability in S7-1200 Devices2021-08-10csaf · siemens_psirtDE

    SIMATIC S7-1200 PLC, version V4.5.0 fails to authenticate against configured passwords when the affected device was provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. Siemens has released an update for SIMATIC S7-1200 and recommends to update to the latest version.

  • ICSA-21-222-09Siemens SIMATIC S7-1200 (Update A)2021-08-10icsa · cisa_csaf_otUS

    SIMATIC S7-1200 PLC, version V4.5.0 fails to authenticate against configured passwords when the affected device was provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. Siemens has released an update for SIMATIC S7-1200 and recommends to update to the latest version.

06

also known as (3)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

08

references (8)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan