CVE-2021-26845

mediumpriority · track · 30OT risk · elevatedEPSS 0.009 · 61 %ileEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
0.93% (61st) EPSS
CVSS 5 · medium
Is it mine?
12 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. This issue affects: Hitachi ABB Power Grids eSOMS 6.0 versions prior to 6.0.4.2.2; 6.1 versions prior to 6.1.4; 6.3 versions prior to 6.3.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedeSOMScisa_csaf_ot

    eSOMS: version 6.0.4.2.2

    https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8942&LanguageCode=en&DocumentPartId=&Action=Launch
  • MitigationeSOMScisa_csaf_ot

    Recommended security practices and firewall configurations can help protect an organization network from attacks that originate from outside the network. Such practices include ensuring critical systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall that has a minimal number of ports exposed, and others that must be evaluated case by case. Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.5
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5–7.5

v2.05mediumAV:N/AC:L/Au:N/C:P/I:N/A:Nprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nprimary · NVD / NIST USexploitability 3.9 · impact 3.6
v3.07.5highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nsecondary · CISA US
v3.17.5highAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nsecondary · ENISA EU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:Nsecondary · cve@mitre.org USexploitability 3.9 · impact 3.6
v3.16.9mediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (12)

Products and version ranges known to be affected.

05

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-21-077-02Hitachi ABB Power Grids eSOMS2021-03-18icsa · cisa_csaf_otUS

    Successful exploitation of this vulnerability could allow an attacker to gain access to unauthorized information.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (5)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan