A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)siemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC WinCC Runtime Advanced V15siemens_psirt
Update to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC WinCC Runtime Advanced V16siemens_psirt
Update to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776018/ - FixedSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V15.1 Update 6, and then update panel to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Update SIMATIC WinCC (TIA Portal) to V16 Update 4 or later version, and then update panel to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109775861/ - FixedSIMATIC WinCC Runtime Advanced V15cisa_csaf_ot
Update to V15.1 Update 6
https://support.industry.siemens.com/cs/ww/en/view/109763890/ - FixedSIMATIC WinCC Runtime Advanced V16cisa_csaf_ot
Update to V16 Update 4 or later version
https://support.industry.siemens.com/cs/ww/en/view/109776018/ - MitigationSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fsiemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V15siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V16siemens_psirt
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants)cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900Fcisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V15cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
- MitigationSIMATIC WinCC Runtime Advanced V16cisa_csaf_ot
Restrict access to port 5900/tcp to trusted IP addresses only
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5–7.5
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (72)
Products and version ranges known to be affected.
- Siemens SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)All versions → V15.1 Update 6enisa_euvdEU
- Siemens SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants)All versions → V16 Update 4enisa_euvdEU
- Siemens SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants)All versions → V15.1 Update 6enisa_euvdEU
- Siemens SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants)All versions → V16 Update 4enisa_euvdEU
advisories (2)
Vendor and ecosystem advisories describing this.
- SSA-538778SSA-538778: SmartVNC Vulnerabilities in SIMATIC HMI/WinCC Products2021-05-11csaf · siemens_psirtDE
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
- ICSA-21-131-12Siemens SIMATIC SmartVNC HMI WinCC Products (Update B)2021-05-11icsa · cisa_csaf_otUS
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (7)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2021-25660cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12cnnvd
- https://vigilance.fr/vulnerability/SmartVNC-multiple-vulnerabilities-35360cnnvd
- https://www.cybersecurity-help.cz/vdb/SB2021051206cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdfPatchVendor Advisorynvd