CVE-2021-22797
highpriority · track · 40EPSS 0.261 · 98 %ileEUUSEPSS · scored 2026-10-27
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedEcoStruxure Control Expertcisa_csaf_ot
Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.
- FixedEcoStruxure Process Expertcisa_csaf_ot
Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.
- FixedSCADAPack RemoteConnect for x70cisa_csaf_ot
Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.
- MitigationEcoStruxure Control Expertcisa_csaf_ot
Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.
- MitigationEcoStruxure Process Expertcisa_csaf_ot
Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.
- MitigationSCADAPack RemoteConnect for x70cisa_csaf_ot
Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (12)
Products and version ranges known to be affected.
- schneider-electric ecostruxure control expert< 15.1nvdUScpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure process expert< 2021nvdUScpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*
- schneider-electric remoteconnectall versionsnvdUScpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:*:*
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-21-259-02Schneider Electric EcoStruxure and SCADAPack2021-09-16icsa · cisa_csaf_otUS
Successful exploitation of this vulnerability could result in code execution on the engineering workstation.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (6)
External citations — patches, advisories, analysis.
- https://cxsecurity.com/cveshow/CVE-2021-22797/cnnvd
- https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-01Patchcnnvd
- https://www.se.com/ww/en/download/document/SEVD-2021-257-01/cnnvd
- https://www.zerodayinitiative.com/advisories/ZDI-21-1102/cnnvd
- https://www.se.com/ww/en/download/document/SEVD-2021-257-01/enisa_euvd
- https://www.se.com/ww/en/download/document/SEVD-2021-257-01/MitigationPatchVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan