CVE-2020-9273

highpriority · attend · 49EPSS 0.121 · 96 %ileexploit · PoCDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
12.1% (96th) EPSS
CVSS 9 · high
Is it mine?
28 products
Check your exposure
Who says so?
6 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

In ProFTPD 1.3.7, it is possible to corrupt the memory pool by interrupting the data transfer channel. This triggers a use-after-free in alloc_pool in pool.c, and possible remote code execution.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.0
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.09highAV:N/AC:L/Au:S/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 8 · impact 10
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 2.8 · impact 5.9
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:Csecondary · CISA US
v3.18.8highAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:Csecondary · Siemens ProductCERT DE
v3.18.3highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:Psecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

exploits (1)

Public proof-of-concept and weaponised exploit code.

05

affected products (28)

Products and version ranges known to be affected.

06

advisories (2)

Vendor and ecosystem advisories describing this.

  • SSA-679335SSA-679335: Multiple Vulnerabilities in Embedded FTP Server of SIMATIC CP Modules2021-08-10csaf · siemens_psirtDE

    SIMATIC CP 1543-1 and CP 1545-1 devices are affected by multiple vulnerabilities in ProFTPD, a third party component, that could allow a remote attacker to access sensitive information and execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • ICSA-21-222-07Siemens SIMATIC CP (Update A)2021-08-10icsa · cisa_csaf_otUS

    SIMATIC CP 1543-1 and CP 1545-1 devices are affected by multiple vulnerabilities in ProFTPD, a third party component, that could allow a remote attacker to access sensitive information and execute arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

10

references (45)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan