CVE-2020-7546
lowpriority · track · 22EPSS 0.006 · 49 %ileEUUSEPSS · scored 2026-10-23
A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 3.5–5.4
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (10)
Products and version ranges known to be affected.
- n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)≤ EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)enisa_euvdEU
- schneider-electric ecostruxure energy expert= 2.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_energy_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 7.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 8.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 9.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.1nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.2nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.3nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric powerscada expert with advanced reporting and dashboards= 8.0nvdUScpe:2.3:a:schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards:*:*:*:*:*:*:*:*
- schneider-electric powerscada operation with advanced reporting and dashboards= 9.0nvdUScpe:2.3:a:schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards:*:*:*:*:*:*:*:*