CVE-2020-7545
mediumpriority · track · 30EPSS 0.021 · 81 %ileEUUSEPSS · scored 2026-10-28
A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 6.5–7.2
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (10)
Products and version ranges known to be affected.
- n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)≤ EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)enisa_euvdEU
- schneider-electric ecostruxure energy expert= 2.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_energy_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 7.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 8.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric ecostruxure power monitoring expert= 9.0nvdUScpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.1nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.2nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric power manager= 1.3nvdUScpe:2.3:a:schneider-electric:power_manager:*:*:*:*:*:*:*:*
- schneider-electric powerscada expert with advanced reporting and dashboards= 8.0nvdUScpe:2.3:a:schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards:*:*:*:*:*:*:*:*
- schneider-electric powerscada operation with advanced reporting and dashboards= 9.0nvdUScpe:2.3:a:schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards:*:*:*:*:*:*:*:*
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan