CVE-2020-26146
lowpriority · track · 23EPSS 0.056 · 93 %ileDEEUNLRUUSEPSS · scored 2026-10-26
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can abuse this to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note that WEP is vulnerable to this attack by design.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)siemens_psirt
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)siemens_psirt
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedCisco Aironet Access Point Softwarecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedCisco Aironet Access Point Software (IOS XE Controller)cisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedCisco Business Wireless Access Point Softwarecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedCisco IP Phones with Multiplatform Firmwarecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedCisco TelePresence Endpoint Software (TC/CE)cisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedCisco Webex Room Phonecisco_csaf
Cisco has released software updates that address this vulnerability.
https://software.cisco.com - FixedTropOScisa_csaf_ot
Disable the Wi-Fi access on any TropOS unit where local Wi-Fi access is not required. This is achieved by NOT enabling (or disabling) the local access SSID.
- FixedSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
Update to V8.7.1.3 or later version
https://support.industry.siemens.com/cs/ww/en/view/109802805/ - FixedSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)cisa_csaf_ot
Update to V3.0.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109808629/ - FixedSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)cisa_csaf_ot
Update to V6.6.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109996102/ - FixedSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - FixedSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
Update to V1.2.0 or later version
https://support.industry.siemens.com/cs/ww/en/view/109805887/ - MitigationSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)siemens_psirt
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationTropOScisa_csaf_ot
As the FragAttacks vulnerability is targeted at an end-user device and generally involves redirection to fraudulent websites, the installation of comprehensive firewall capabilities on company end-user devices and servers will significantly reduce the likelihood of negative outcomes.
- MitigationGT25-WLANcisa_csaf_ot
After writing the required package data to the GOT, refer to the “How to check the versions in use” and check the fixed versions.
- MitigationSCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W738-1 M12 (6GK5738-1GY00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W738-1 M12 (6GK5738-1GY00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 M12 (6GK5748-1GD00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 M12 (6GK5748-1GD00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 (6GK5778-1GY00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 (6GK5778-1GY00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 SFP (6GK5786-2FE00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2 SFP (6GK5786-2FE00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 M12 (6GK5788-1GD00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 M12 (6GK5788-1GD00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 (6GK5788-2GD00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 (6GK5788-2GD00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM763-1 (6GK5763-1AL00-7DA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 (6GK5766-1GE00-7DA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM763-1 (6GK5763-1AL00-3AA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM763-1 (6GK5763-1AL00-3DA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM766-1 (6GK5766-1GE00-3DA0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
- MitigationSCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0)cisa_csaf_ot
As these vulnerabilities can only be exploited within Wi-Fi range, when possible reduce Wi-Fi transmission power or make sure to have the devices in private areas with physical access controls
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2.9–5.3
ssvc
A stakeholder decision — act, attend, or track — from exploitation and impact.
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (378)
Products and version ranges known to be affected.
advisories (10)
Vendor and ecosystem advisories describing this.
- NCSC-2026-0112Kwetsbaarheden verholpen in Siemens productenNL2026-04-14csaf · ncsc_nlNL
Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Analytics Toolkit, Ruggedcom, Industrial Edge Management Pro, SIDIS en TPM.
- SSA-019200SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.02026-04-14csaf · siemens_psirtDE
SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.
- SSA-913875SSA-913875: Frame Aggregation and Fragmentation Vulnerabilities in 802.112021-07-13csaf · siemens_psirtDE
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The advised Siemens products are only affected by some of the published vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- WID-SEC-W-2022-2069IEEE 802.11 (WLAN): Mehrere SchwachstellenDeutsch2021-05-11csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in der IEEE 802.11 Spezifikation und zahlreichen Implementierungen ausnutzen, um Sicherheitsvorkehrungen zu umgehen, Netzwerkverkehr zu manipulieren und um Informationen offenzulegen.
- cisco-sa-wifi-faf-22epcEWuMultiple Vulnerabilities in Frame Aggregation and Fragmentation Implementations of 802.11 Specification Affecting Cisco Products: May 20212021-05-11csaf · cisco_csafUS
On May 11, 2021, the research paper Fragment and Forge: Breaking Wi-Fi Through Frame Aggregation and Fragmentation was made public. This paper discusses 12 vulnerabilities in the 802.11 standard. One vulnerability is in the frame aggregation functionality, two vulnerabilities are in the frame fragmentation functionality, and the other nine are implementation vulnerabilities. These vulnerabilities could allow an attacker to forge encrypted frames, which could in turn enable the exfiltration of sensitive data from a targeted device. This advisory will be updated as additional information becomes available.
- ICSA-21-236-01Hitachi ABB Power Grids TropOS2021-08-24icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could allow an attacker to direct a client that is connected to a TropOS Wi-Fi access point to fake websites and extract sensitive data.
- ICSA-22-102-04Mitsubishi Electric GT25-WLAN2022-04-12icsa · cisa_csaf_otUS
There are multiple vulnerabilities due to design flaws in the frame fragmentation functionality and the frame aggregation functionality in the Wireless Communication Standards IEEE 802.11. These vulnerabilities could allow an attacker to steal communication contents or inject unauthorized packets.
- ICSA-22-104-04Siemens SCALANCE FragAttacks2021-07-13icsa · cisa_csaf_otUS
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The advised Siemens products are only affected by some of the published vulnerabilities. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
- ICSA-26-111-07Siemens SCALANCE2026-04-14icsa · cisa_csaf_otUS
SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.
- ASB-A-1756268082021-10-01vendor · osvUS
also known as (7)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (45)
External citations — patches, advisories, analysis.
- http://www.openwall.com/lists/oss-security/2021/05/11/12cnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-019200.htmlcnnvd
- https://cert-portal.siemens.com/productcert/html/ssa-913875.htmlcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdfcnnvd
- https://device.harmonyos.com/cn/docs/security/update/security-bulletins-phones-202111-0000001218088197cnnvd
- https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.mdcnnvd
- https://packetstormsecurity.com/files/164875/Red-Hat-Security-Advisory-2021-4140-02.htmlcnnvd
- https://source.android.com/security/bulletin/2021-10-01cnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan