CVE-2020-15790
mediumpriority · track · 21EPSS 0.009 · 60 %ileEUUSEPSS · scored 2026-10-28
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
No vendor fix yet; a mitigation is available.
- MitigationSpectrum Power' 4cisa_csaf_ot
Siemens offers mitigations for customers. Please contact your local Siemens representative for further information.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 3.7–5.3
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (5)
Products and version ranges known to be affected.
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-20-252-04Siemens Spectrum Power2020-09-08icsa · cisa_csaf_otUS
Operators of critical power systems (e.g.'TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g.'firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Digital Grid Products can be found at:
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (6)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdfcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2020-15790cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-20-252-04cnnvd
- https://www.auscert.org.au/bulletins/ESB-2020.3091/cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdfenisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-568969.pdfVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan