SQLite before 3.32.0 allows a virtual table to be renamed to the name of one of its shadow tables, related to alter.c and build.c.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedAbility Camera Connectabb_psirt
The problem is corrected in the following product versions: - ABB Ability Camera Connect 2.0.0.49. The easiest path to mitigate the problem is an update of ABB Ability Camera Connect system by the customer. ABB recommends that customers apply the update at earliest convenience.
- FixedAutomation Studioabb_psirt
The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
- FixedSINEC INSsiemens_psirt
Update to V1.0.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806100/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)siemens_psirt
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSINEC INScisa_csaf_ot
Update to V1.0.1.1 or later version
https://support.industry.siemens.com/cs/ww/en/view/109806100/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Update to V3.1.5 or later version
https://support.industry.siemens.com/cs/ww/en/view/109478459/ - FixedB&R Automation Studiocisa_csaf_ot
The problem is corrected in the following product versions: B&R Automation Studio 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
- MitigationAbility Camera Connectabb_psirt
This vulnerability involves database schema manipulation: - Administrative Privilege Requirement: Renaming tables requires database administrative privileges, which are not granted to normal Camera Connect users. - Virtual Table Usage: This vulnerability specifically affects virtual tables, which are an advanced SQLite feature. Camera Connect's database schema uses standard tables for its operational data. - Schema Stability: In industrial OT environments, database schemas are static and controlled through formal change management processes. Dynamic table creation and renaming are not typical operational activities. - Limited Impact: Even if exploited, the impact is primarily on database integrity rather than system availability or confidentiality. Database backups and recovery procedures in industrial environments provide restoration capabilities. - Application Logic: Camera Connect's application layer mediates all database interactions, preventing direct DDL (Data Definition Language) operations by end users. The requirement for administrative access and the uncommon use case of dynamic schema modification in OT environments make this vulnerability low risk for Camera Connect.
- MitigationAutomation Studioabb_psirt
Refer to section “General security recommendations” for advice on how to keep your system secure.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationSIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)cisa_csaf_ot
Only build and run applications from trusted sources.
- MitigationB&R Automation Studiocisa_csaf_ot
Refer to section “General security recommendations” for advice on how to keep your system secure.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 2.1–5.5
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (66)
Products and version ranges known to be affected.
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
- Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)≤ vers:intdot/>=3.1.0|<3.1.5cisa_csaf_otUS
advisories (12)
Vendor and ecosystem advisories describing this.
- 4HZM000604ABB Ability Camera Connect Vulnerabilities in outdated 3rd party component (SQLite 3.2.4)2026-03-26csaf · abb_psirtCH
ABB is aware of public reports of vulnerabilities in a 3rd party dependency SQLite Version 3.2.4 which was delivered together with the installation package of Camera Connect Version 2.0.0.42 and below. An update is available that resolves a privately reported outdated 3rd party component with vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited any of these vulnerabilities in the 3rd party component could potentially compromise the system in different ways.
- SA25P007B&R Automation Studio Update of SQLite version2026-02-18csaf · abb_psirtCH
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.
- SSA-389290SSA-389290: Third-Party Component Vulnerabilities in SINEC INS2022-03-08csaf · siemens_psirtDE
71 vulnerabilities in third-party components as Node.js, cURL, SQLite, CivetWeb and DNS(ISC BIND) could allow an attacker to interfere with the affected product in various ways. Siemens has released an update for SINEC INS and recommends to update to the latest versions.
- SSA-398330SSA-398330: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.52023-12-12csaf · siemens_psirtDE
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP >= V3.1.0 and < V3.1.5 are no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 (https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- WID-SEC-W-2023-0856IBM QRadar SIEM: Mehrere SchwachstellenDeutsch2022-05-31csaf · cert_bundDE
Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in IBM QRadar SIEM ausnutzen, um die Vertraulichkeit, Integrität und Verfügbarkeit zu gefährden.
- WID-SEC-W-2023-1614Tenable Security Nessus Network Monitor: Mehrere SchwachstellenDeutsch2023-06-29csaf · cert_bundDE
Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in Tenable Security Nessus Network Monitor ausnutzen, um beliebigen Code auszuführen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszulösen und Daten zu manipulieren.
- WID-SEC-W-2024-3402F5 BIG-IP: Schwachstelle ermöglicht Manipulation von DateienDeutsch2024-11-11csaf · cert_bundDE
Ein lokaler Angreifer kann eine Schwachstelle in F5 BIG-IP ausnutzen, um Dateien zu manipulieren.
- WID-SEC-W-2026-0180Dell Data Protection Advisor: Mehrere SchwachstellenDeutsch2026-01-20csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell Data Protection Advisor ausnutzen, um beliebigen Code auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Sicherheitsmaßnahmen zu umgehen und nicht näher spezifizierte Angriffe zu starten.
- ICSA-22-069-09Siemens SINEC INS2022-03-08icsa · cisa_csaf_otUS
71 vulnerabilities in third-party components as Node.js, cURL, SQLite, CivetWeb and DNS(ISC BIND) could allow an attacker to interfere with the affected product in various ways. Siemens has released an update for SINEC INS and recommends to update to the latest versions.
- ICSA-23-348-10Siemens SIMATIC S7-15002023-12-12icsa · cisa_csaf_otUS
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version >= V3.1.0 and < V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). These GNU/Linux vulnerabilities have been externally identified. Siemens has released new versions for the affected products and recommends to update to the latest versions. Note: This SSA advises vulnerabilities for firmware version V3.1 only; for versions < V3.1 refer to Siemens Security Bulletin SSB-439005 ( https://cert-portal.siemens.com/productcert/html/ssb-439005.html).
- ICSA-26-141-03ABB B&R Automation Studio2026-02-18icsa · cisa_csaf_otUS
ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is available that replaces an outdated third-party component. Although no successful exploitation was observed during testing of the affected B&R products, the identified vulnerabilities could present potential attack vectors that might enable unauthorized access, data exposure, or remote code execution.
- BIT-sqlite-2020-136312024-03-06vendor · osvUS
SQLite before 3.32.0 allows a virtual table to be renamed to the name of one of its shadow tables, related to alter.c and build.c.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (103)
External citations — patches, advisories, analysis.
- http://seclists.org/fulldisclosure/2020/Dec/32cnnvd
- http://seclists.org/fulldisclosure/2020/Nov/19cnnvd
- http://seclists.org/fulldisclosure/2020/Nov/20cnnvd
- http://seclists.org/fulldisclosure/2020/Nov/22cnnvd
- http://www.nsfocus.net/vulndb/46787cnnvd
- https://bugs.chromium.org/p/chromium/issues/detail?id=1080459cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfcnnvd
- https://lists.apache.org/thread.html/rc713534b10f9daeee2e0990239fa407e2118e4aa9e88a7041177497c@%3Cissues.guacamole.apache.org%3Ecnnvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan