A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 6.4–9.1
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (28)
Products and version ranges known to be affected.
- Siemens AG SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900FAll versions → V15.1 Update 1enisa_euvdEU
- siemens simatic hmi comfort outdoor panels firmware< 15.1nvdUScpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*
- siemens simatic hmi comfort panels firmware< 15.1nvdUScpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*
- siemens simatic hmi ktp mobile panels ktp400f firmware< 15.1nvdUScpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*
- siemens simatic hmi ktp mobile panels ktp700 firmware< 15.1nvdUScpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (16)
External citations — patches, advisories, analysis.
- http://subscriber.communications.siemens.com/cnnvd
- http://www.securityfocus.com/bid/108412cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdfcnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-19-134-02-0cnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-19-134-09cnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2019-6572cnnvd
- https://vigilance.fr/vulnerability/SIMATIC-WinCC-multiple-vulnerabilities-29288cnnvd
- https://www.auscert.org.au/bulletins/80946cnnvd