CVE-2019-6570

highpriority · track · 35OT risk · elevatedEPSS 0.013 · 71 %ileEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.33% (71st) EPSS
CVSS 9 · high
Is it mine?
9 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-26

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSINEMA Remote Connect Clientcisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Servercisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Servercisa_csaf_ot

    Update to V2.0

  • MitigationSINEMA Remote Connect Clientcisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

  • MitigationSINEMA Remote Connect Servercisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

02

cvss

Technical severity, 0–10. One row per scoring source.

9.0
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.09highAV:N/AC:L/Au:S/C:C/I:C/A:Cprimary · NVD / NIST USexploitability 8 · impact 10
v3.18.8highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 2.8 · impact 5.9
v3.18.3highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.18.8highAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.18.1highCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (9)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • ICSA-19-099-04Siemens SINEMA Remote Connect (Update A)2019-04-09icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to circumvent the system authorization for certain functionalities, and to execute privileged functions.

  • ICSA-21-068-10Siemens SCALANCE and SIMATIC libcurl (Update B)2019-04-09icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

08

references (9)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan