CVE-2019-3823

mediumpriority · track · 31EPSS 0.041 · 91 %ileDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
4.12% (91st) EPSS
CVSS 5 · medium
Is it mine?
33 products
Check your exposure
Who says so?
8 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-22

libcurl versions from 7.34.0 to before 7.64.0 are vulnerable to a heap out-of-bounds read in the code handling the end-of-response for SMTP. If the buffer passed to `smtp_endofresp()` isn't NUL terminated and contains no character ending the parsed number, and `len` is set to 5, then the `strtol()` call reads beyond the allocated buffer. The read contents will not be returned to the caller.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSCALANCE SC600 Familysiemens_psirt

    Update to V2.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109769665/
  • FixedSIMATIC CM 1542-1siemens_psirt

    Update to V3.0 or later version

    https://support.industry.siemens.com/cs/ww/en/view/109801629/
  • FixedSINEMA Remote Connect Clientcisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Servercisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Clientcisa_csaf_ot

    Update to V2.0 HF1

  • MitigationSCALANCE SC600 Familysiemens_psirt

    Disable the SMTP Client function on affected devices or use VPN for protecting SMTP traffic to trusted email servers only

  • MitigationSIMATIC CM 1542-1siemens_psirt

    Disable the SMTP Client function on affected devices or use VPN for protecting SMTP traffic to trusted email servers only

  • MitigationSIMATIC CP 343-1 Advanced (incl. SIPLUS variants)siemens_psirt

    Disable the SMTP Client function on affected devices or use VPN for protecting SMTP traffic to trusted email servers only

  • MitigationSINEMA Remote Connect Clientcisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

  • MitigationSINEMA Remote Connect Servercisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

  • MitigationSINEMA Remote Connect Clientcisa_csaf_ot

    Turn off SMTP to mitigate CVE-2019-3823

  • No fix availableSIMATIC CP 343-1 Advanced (incl. SIPLUS variants)siemens_psirt

    Currently no remediation is available

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 4.3–9.8

v2.05mediumAV:N/AC:L/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.07.5highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 3.6
v3.06.9mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Usecondary · CVSS-BT (t0sche)
v3.04.3mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:Nsecondary · ENISA EU
v3.04.3mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:Nsecondary · secalert@redhat.com USexploitability 2.8 · impact 1.4
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (33)

Products and version ranges known to be affected.

06

advisories (7)

Vendor and ecosystem advisories describing this.

  • SSA-936080SSA-936080: Multiple Vulnerabilities in Third-Party Component libcurl2021-03-09csaf · siemens_psirtDE

    SIMATIC CM 1542-1, SCALANCE SC600 family and SIMATIC CP 343-1 Advanced devices are vulnerable to a vulnerability in the third party component libcurl that could allow an attacker to cause a Denial-of-Service condition on the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or not yet available. The impact of additional libcurl vulnerabilities is described in Siemens Security Advisory SSA-436177.

  • WID-SEC-W-2023-1640cURL: Mehrere SchwachstellenDeutsch2019-02-05csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in cURL ausnutzen, um Informationen offenzulegen oder einen Denial of Service Angriff durchzuführen.

  • WID-SEC-W-2025-1212Oracle Communications Applications: Mehrere SchwachstellenDeutsch2019-04-16csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Oracle Communications Applications ausnutzen, um dadurch die Integrität, Vertraulichkeit und Verfügbarkeit zu gefährden.

  • WID-SEC-W-2026-0180Dell Data Protection Advisor: Mehrere SchwachstellenDeutsch2026-01-20csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Dell Data Protection Advisor ausnutzen, um beliebigen Code auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Sicherheitsmaßnahmen zu umgehen und nicht näher spezifizierte Angriffe zu starten.

  • ICSA-19-099-04Siemens SINEMA Remote Connect (Update A)2019-04-09icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to circumvent the system authorization for certain functionalities, and to execute privileged functions.

  • ICSA-21-068-10Siemens SCALANCE and SIMATIC libcurl (Update B)2019-04-09icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

  • CURL-CVE-2019-3823SMTP end-of-response out-of-bounds read2019-02-06vendor · osvUS

    libcurl contains a heap out-of-bounds read in the code handling the end-of-response for SMTP. If the buffer passed to `smtp_endofresp()` is not null-terminated and contains no character ending the parsed number, and `len` is set to 5, then the `strtol()` call reads beyond the allocated buffer. The read content is not returned to the caller.

07

also known as (5)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

09

references (61)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan