CVE-2019-20633
mediumpriority · track · 22EPSS 0.010 · 63 %ileDEEUUSEPSS · scored 2026-10-27
GNU patch through 2.7.6 contains a free(p_line[p_end]) Double Free vulnerability in the function another_hunk in pch.c that can cause a denial of service via a crafted patch file. NOTE: this issue exists because of an incomplete fix for CVE-2018-6952.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedFirmware < 2025.0.2 installed on AXC F 1152phoenix_contact_psirt
Update to the latest 2025.0.2 Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- FixedFirmware < 2025.0.2 installed on AXC F 2152phoenix_contact_psirt
Update to the latest 2025.0.2 Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- FixedFirmware < 2025.0.2 installed on AXC F 3152phoenix_contact_psirt
Update to the latest 2025.0.2 Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- FixedFirmware < 2025.0.2 installed on BPC 9102Sphoenix_contact_psirt
Update to the latest 2025.0.2 Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
- FixedFirmware < 2025.0.2 installed on RFC 4072Sphoenix_contact_psirt
Update to the latest 2025.0.2 Firmware Release. PHOENIX CONTACT recommends to always use an up-to-date version of the PLCnext Engineer.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (31)
Products and version ranges known to be affected.
- Dell PowerProtect Data Domain Management Centerall versionscert_bundDEcpe:/a:dell:powerprotect_data_domain_management_center:-
advisories (2)
Vendor and ecosystem advisories describing this.
- VDE-2025-053Phoenix Contact: Multiple Vulnerabilities in PLCnext Firmware2025-07-08csaf · phoenix_contact_psirtDE
Multiple Linux component vulnerabilities fixed in latest PLCnext Firmware release 2025.0.2
- WID-SEC-W-2025-0225Dell PowerProtect Data Domain: Mehrere SchwachstellenDeutsch2025-01-30csaf · cert_bundDE
Ein Angreifer kann mehrere Schwachstellen in Dell PowerProtect Data Domain ausnutzen, um erhöhte Rechte zu erlangen, einen Denial-of-Service-Zustand herbeizuführen und einen nicht näher spezifizierten Angriff durchzuführen.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (4)
External citations — patches, advisories, analysis.
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan