CVE-2019-19294
lowpriority · track · 14EPSS 0.010 · 63 %ileDEEURUUSEPSS · scored 2026-10-27
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains multiple stored Cross-site Scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedControl Center Server (CCS)siemens_psirt
Update to V1.5.0 or later version
- FixedControl Center Server (CCS)cisa_csaf_ot
Update to V1.5.0 or later version
- FixedControl Center Server (CCS)cisa_csaf_ot
Update to V1.5.0 or later version
https://sivms.cloud/control-center-server-ccs/ - MitigationControl Center Server (CCS)siemens_psirt
Apply ACL/firewall configuration on the CCS server to ensure that only legitimate systems are able to access the configured CCS server ports. Harden the CCS server accordingly to prevent unauthorized access. Consider to apply encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).
- MitigationControl Center Server (CCS)cisa_csaf_ot
Apply ACL/firewall configuration on the CCS server to ensure that only legitimate systems are able to access the configured CCS server ports. Harden the CCS server accordingly to prevent unauthorized access. Consider to apply encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).
- MitigationControl Center Server (CCS)cisa_csaf_ot
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · low–medium · 3–6.3
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (7)
Products and version ranges known to be affected.
- siemens sinvr 3 central control serverall versionsnvdUScpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*
advisories (3)
Vendor and ecosystem advisories describing this.
- SSA-761844SSA-761844: Multiple Vulnerabilities in Control Center Server (CCS)2021-04-13csaf · siemens_psirtDE
The advisory informs about multiple vulnerabilities in the Central Control Server (CCS) application, as initially reported in SSA-761617 ( https://cert-portal.siemens.com/productcert/html/ssa-761617.html) on 2019-12-10 and SSA-844761 (https://cert-portal.siemens.com/productcert/html/ssa-844761.html) on 2020-03-10. The vulnerabilities involve authentication bypass (CVE-2019-18337, CVE-2019-18341), path traversal (CVE-2019-18338, CVE-2019-19290), information disclosure (CVE-2019-13947, CVE-2019-18340, CVE-2019-19291), privilege escalation (CVE-2019-18342), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), and insufficient logging (CVE-2019-19295). PKE has released an update for CCS that fixes the reported vulnerabilities, except for CVE-2019-18340. For details contact PKE ( https://pke.at/). Siemens recommends to update to the latest version and recommends specific countermeasures to mitigate the vulnerabilities.
- ICSA-20-070-01ICSA-20-070-01_Siemens and PKE SiNVR/SiVMS Video Server (Update B)2021-04-13icsa · cisa_csaf_otUS
The advisory informs about multiple vulnerabilities in the Central Control Server (CCS) application, as initially reported in SSA-761617 ( https://cert-portal.siemens.com/productcert/html/ssa-761617.html) on 2019-12-10 and SSA-844761 (https://cert-portal.siemens.com/productcert/html/ssa-844761.html) on 2020-03-10. The vulnerabilities involve authentication bypass (CVE-2019-18337, CVE-2019-18341), path traversal (CVE-2019-18338, CVE-2019-19290), information disclosure (CVE-2019-13947, CVE-2019-18340, CVE-2019-19291), privilege escalation (CVE-2019-18342), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), and insufficient logging (CVE-2019-19295). PKE has released an update for CCS that fixes the reported vulnerabilities, except for CVE-2019-18340. For details contact PKE ( https://pke.at/). Siemens recommends to update to the latest version and recommends specific countermeasures to mitigate the vulnerabilities.
- ICSA-21-103-10Siemens and PKE Control Center Server2021-04-13icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities may allow an attacker to read and write arbitrary files and sensitive data and execute commands and arbitrary code.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (11)
External citations — patches, advisories, analysis.
- http://www.nsfocus.net/vulndb/46128cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdfcnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdfcnnvd
- https://nvd.nist.gov/vuln/detail/CVE-2019-19294cnnvd
- https://us-cert.cisa.gov/ics/advisories/icsa-21-103-10cnnvd
- https://www.auscert.org.au/bulletins/ESB-2021.1240cnnvd
- https://www.us-cert.gov/ics/advisories/icsa-20-070-01cnnvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdfenisa_euvd