CVE-2018-16890

mediumpriority · track · 42EPSS 0.054 · 93 %ileexploit · PoCDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
Public exploit
1 exploit · PoC
Likely / severe?
5.35% (93rd) EPSS
CVSS 5 · medium
Is it mine?
35 products
Check your exposure
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cert_bund

EPSS · scored 2026-10-27

libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedSINEMA Remote Connect Clientcisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Servercisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890 and CVE-2019-3822

  • FixedSINEMA Remote Connect Clientcisa_csaf_ot

    Update to V2.0 HF1

  • MitigationSINEMA Remote Connect Clientcisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

  • MitigationSINEMA Remote Connect Servercisa_csaf_ot

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity

  • MitigationSINEMA Remote Connect Clientcisa_csaf_ot

    Turn off NTLM authentication to mitigate CVE-2018-16890

02

cvss

Technical severity, 0–10. One row per scoring source.

7.5
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 5–7.5

v2.05mediumAV:N/AC:L/Au:N/C:N/I:N/A:Pprimary · NVD / NIST USexploitability 10 · impact 2.9
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 3.6
v3.05.4mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:Lsecondary · ENISA EU
v3.05.4mediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:Lsecondary · secalert@redhat.com USexploitability 2.8 · impact 2.5
v3.17.5highAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.17.5highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.17.1highCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:Psecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

exploits (1)

Public proof-of-concept and weaponised exploit code.

06

affected products (35)

Products and version ranges known to be affected.

07

advisories (6)

Vendor and ecosystem advisories describing this.

  • WID-SEC-W-2023-1640cURL: Mehrere SchwachstellenDeutsch2019-02-05csaf · cert_bundDE

    Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in cURL ausnutzen, um Informationen offenzulegen oder einen Denial of Service Angriff durchzuführen.

  • WID-SEC-W-2025-1212Oracle Communications Applications: Mehrere SchwachstellenDeutsch2019-04-16csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Oracle Communications Applications ausnutzen, um dadurch die Integrität, Vertraulichkeit und Verfügbarkeit zu gefährden.

  • WID-SEC-W-2026-0180Dell Data Protection Advisor: Mehrere SchwachstellenDeutsch2026-01-20csaf · cert_bundDE

    Ein Angreifer kann mehrere Schwachstellen in Dell Data Protection Advisor ausnutzen, um beliebigen Code auszuführen, einen Denial-of-Service-Zustand zu erzeugen, Sicherheitsmaßnahmen zu umgehen und nicht näher spezifizierte Angriffe zu starten.

  • ICSA-19-099-04Siemens SINEMA Remote Connect (Update A)2019-04-09icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to circumvent the system authorization for certain functionalities, and to execute privileged functions.

  • ICSA-21-068-10Siemens SCALANCE and SIMATIC libcurl (Update B)2019-04-09icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

  • CURL-CVE-2018-16890NTLM type-2 out-of-bounds buffer read2019-02-06vendor · osvUS

    libcurl contains a heap buffer out-of-bounds read flaw. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.

08

also known as (5)

Other names and identifiers for this entity.

09

sources

Which sources assert this record, and when.

11

references (51)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan