CVE-2018-11457
highpriority · track · 34EPSS 0.046 · 92 %ileEURUUSEPSS · scored 2026-10-26
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
No vendor fix yet; a mitigation is available.
- MitigationSINUMERIK 808D V4.7cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply Defense-in-Depth
- MitigationSINUMERIK 808D V4.8cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply Defense-in-Depth
- MitigationSINUMERIK 828D V4.7cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply Defense-in-Depth
- MitigationSINUMERIK 840D sl V4.7cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply Defense-in-Depth
- MitigationSINUMERIK 840D sl V4.8cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:firewall on port X130privilege approach Apply Defense-in-Depth
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.4–9.8
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (19)
Products and version ranges known to be affected.
- Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8SINUMERIK 828D V4.7 : All versions → V4.7 SP6 HF1enisa_euvdEU
- Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8SINUMERIK 840D sl V4.7 : All versions → V4.7 SP6 HF5enisa_euvdEU
- Siemens AG SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8SINUMERIK 840D sl V4.8 : All versions → V4.8 SP3enisa_euvdEU
- siemens sinumerik 828d v4.7 firmware≤ 4.7nvdUScpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*
- siemens sinumerik 840d sl v4.7 firmware≤ 4.7nvdUScpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*
- siemens sinumerik 840d sl v4.8 firmware≤ 4.8nvdUScpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-18-345-02ICSA-18-345-02 Siemens SINUMERIK Controllers (Update A)2018-12-11icsa · cisa_csaf_otUS
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (6)
External citations — patches, advisories, analysis.
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdfcnnvd
- https://www.securityfocus.com/bid/106185cnnvd
- http://www.securityfocus.com/bid/106185enisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdfenisa_euvd
- http://www.securityfocus.com/bid/106185Third Party AdvisoryVDB Entrynvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdfVendor Advisorynvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.
Free scan