CVE-2017-2680

mediumpriority · track · 26EPSS 0.011 · 67 %ileDEEURUUS
grimoire priorityP3 · Track
Exploitable?
—
no known exploitation
Likely / severe?
1.15% (67th) EPSS
CVSS 6.1 · medium
Is it mine?
732 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-24

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

7.1
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–high · 4.9–7.1

v2.06.1mediumAV:A/AC:L/Au:N/C:N/I:N/A:Cprimary · NVD / NIST USexploitability 6.5 · impact 6.9
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hprimary · NVD / NIST USexploitability 2.8 · impact 3.6
v3.06.5mediumCVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:Csecondary · CISA US
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · productcert@siemens.com DEexploitability 2.8 · impact 3.6
v3.16.5mediumAV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · FSTEC (BDU) RU
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · Siemens ProductCERT DE
v3.16.5mediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:Hsecondary · CISA US
v4.04.9mediumCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · CVSS-BT (t0sche)
v4.07.1highCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:Nsecondary · ENISA EU
v4.07.1highCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:Xsecondary · productcert@siemens.com DE
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Trackcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

affected products (732)

Products and version ranges known to be affected.

06

advisories (4)

Vendor and ecosystem advisories describing this.

  • SSA-293562SSA-293562: Denial of Service Vulnerabilities in PROFINET DCP Implementation of Industrial Products2017-05-08csaf · siemens_psirtDE

    Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.

  • ICSA-17-129-02Siemens PROFINET DCP (Update V)2017-05-08icsa · cisa_csaf_otUS

    Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.

  • ICSA-18-023-02ICSA-18-023-02 Siemens Industrial Products (Update A)2018-01-18icsa · cisa_csaf_otUS

    CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.

  • ICSA-18-128-01Siemens Medium Voltage SINAMICS Products (Update A)2018-05-03icsa · cisa_csaf_otUS

    As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.

07

also known as (4)

Other names and identifiers for this entity.

08

sources

Which sources assert this record, and when.

10

references (29)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan