Stack buffer overflow in hasplms in Gemalto ACC (Admin Control Center), all versions ranging from HASP SRM 2.10 to Sentinel LDK 7.50, allows remote attackers to execute arbitrary code via language packs containing filenames longer than 1024 characters.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
A vendor fix is available.
- FixedSIMATIC WinCC Add-On Historian CONNECT ALARMcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PI CONNECT ALARMcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PI CONNECT AUDIT TRAILcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-AGENTcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-ANALYZEcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-CONTROLcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-MAINTcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN EXPORTcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN HOST-Scisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN IMPORTcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN PIcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN PV02cisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-OPEN TCP/IPcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On PM-QUALITYcisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On SICEMENT IT MIScisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedSIMATIC WinCC Add-On SIPAPER IT MIScisa_csaf_ot
Update License Manager software - Download: https://supportportal.gemalto.com/csm/?id=kb_article&sys_id=a459d328dba207c8fe0aff3dbf9619ce
https://supportportal.gemalto.com/csm/ - FixedAnnual Shadingcisa_csaf_ot
V1.0.4, V1.1 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedDesigo ABTcisa_csaf_ot
MP1.1 Build 845, MP1.15 Build 360, MP1.16 Build 055, MP1.2 Build 850, MP1.2.1 Build 318, and MP2.1 Build 965 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedDesigo CCcisa_csaf_ot
MP1.1, MP2.0, MP2.1, and MP3.0 Install LMS V2.1 SP4 (2.1.681) or newer. Customers with MP2.1 or older need to upgrade ALM Manager before applying the update to LMS. - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedDesigo Configuration Manager (DCM)cisa_csaf_ot
V6.10.140 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedDesigo XWPcisa_csaf_ot
V5.00.204, V5.00.260, V5.10.142, V5.10.212, V6.00.184, V6.00.342, and V6.10.172 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedLicense Management System (LMS)cisa_csaf_ot
Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedSiteIQ Analyticscisa_csaf_ot
V1.1, V1.2, and V1.3 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - FixedSiveillance Identitycisa_csaf_ot
V1.1 Install LMS V2.1 SP4 (2.1.681) or newer - Download: To update to 2.1.681 follow the instructions at https://support.industry.siemens.com/cs/document/109479834 or contact your local Siemens representative or the Siemens customer support.
https://support.industry.siemens.com/cs/document/109479834 - MitigationSIMATIC WinCC Add-On Historian CONNECT ALARMcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PI CONNECT ALARMcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PI CONNECT AUDIT TRAILcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-AGENTcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-ANALYZEcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-CONTROLcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-MAINTcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN EXPORTcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN HOST-Scisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN IMPORTcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN PIcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN PV02cisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-OPEN TCP/IPcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On PM-QUALITYcisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On SICEMENT IT MIScisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationSIMATIC WinCC Add-On SIPAPER IT MIScisa_csaf_ot
Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:guidelines (seein order to run the devices in a protected IT environment. It is advised to configure the environment according to our operational https://www.siemens.com/cert/operational-guidelines-industrial-security)
https://www.siemens.com/cert/operational - MitigationAll HASP SRM Sentinel HASP and Sentinel LDKcisa_csaf_ot
Gemalto recommends users who have Sentinel LDK run-time environment (RTE) Version 2.10 through Version 7.54 update to Sentinel LDK RTE component Version 7.6, or the latest version. The update was available as of July 2017
https://sentinelcustomer.gemalto.com/sentineldownloads/
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.5–9.8
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (38)
Products and version ranges known to be affected.
- Siemens Desigo ABT≤ MP1.1 Build 845 | MP1.15 Build 360 | MP1.16 Build 055 | MP1.2 Build 850 | MP1.2.1 Build 318 | and MP2.1 Build 965cisa_csaf_otUS
- Siemens Desigo XWP≤ V5.00.204 | V5.00.260 | V5.10.142 | V5.10.212 | V6.00.184 | V6.00.342 | V6.10.172cisa_csaf_otUS
advisories (3)
Vendor and ecosystem advisories describing this.
- ICSA-18-018-01AICSA-18-018-01A Siemens SIMATIC WinCC Add-On (Update A)2018-01-18icsa · cisa_csaf_otUS
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
- ICSA-18-032-03Gemalto Sentinel License Manager2018-02-01icsa · cisa_csaf_otUS
ATTENTION: Remotely exploitable/low skill level to exploit.
- ICSA-18-093-01ICSA-18-093-01 Siemens Building Technologies Products (Update A)2018-03-28icsa · cisa_csaf_otUS
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
also known as (3)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (17)
External citations — patches, advisories, analysis.
- http://www.gemalto.com/Patchcnnvd
- https://ics-cert.kaspersky.com/advisories/2017/07/28/klcert-17-002-sentinel-ldk-rte-language-packs-containing-malformed-filenames-lead-to-remote-code-execution/cnnvd
- https://www.iotvillage.org/slides_dc25/Sergey_Vlad_DEFCON_IOT_Village_Public2017.pptxcnnvd
- http://www.securityfocus.com/bid/102739enisa_euvd
- http://www.securityfocus.com/bid/102906enisa_euvd
- https://cert-portal.siemens.com/productcert/pdf/ssa-727467.pdfenisa_euvd
- https://ics-cert.kaspersky.com/advisories/2017/07/28/klcert-17-002-sentinel-ldk-rte-language-packs-containing-malformed-filenames-lead-to-remote-code-execution/enisa_euvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-018-01enisa_euvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.