CVE-2017-11317

highpriority · act · 90OT risk · criticalKEV · exploitedEPSS 0.842 · 100 %ileexploit · weaponizedEURUUS
grimoire priorityP0 · Act now
Exploitable?
Yes · in the wild
CISA KEV · 5 exploits · weaponized
Likely / severe?
84.2% (100th) EPSS
CVSS 7.5 · high
Is it mine?
9 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

added 2022-04-11remediate by 2022-05-02

required action Apply updates per vendor instructions.

EPSS · scored 2026-10-26

Telerik UI for ASP.NET AJAX Unrestricted File Upload Vulnerability

Telerik.Web.UI in Progress Telerik UI for ASP.NET AJAX before R1 2017 and R2 before R2 2017 SP2 uses weak RadAsyncUpload encryption, which allows remote attackers to perform arbitrary file uploads or execute arbitrary code.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

  • FixedeSOMScisa_csaf_ot

    Hitachi ABB Power Grids has published an advisory for eSOMS Telerik and advises users to update to eSOMS Version 6.3 as soon as possible.

    https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A8943&LanguageCode=en&DocumentPartId=&Action=Launch
  • MitigationeSOMScisa_csaf_ot

    Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include ensuring applications and servers are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Sensitive application servers should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

02

cvss

Technical severity, 0–10. One row per scoring source.

9.8
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · high–critical · 7.5–9.8

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USexploitability 10 · impact 6.4
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hprimary · NVD / NIST USexploitability 3.9 · impact 5.9
v3.09.8criticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · CISA US
v3.19.8criticalAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · FSTEC (BDU) RU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondary · ENISA EU
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:Hsecondaryexploitability 3.9 · impact 5.9
v3.19.8criticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:Hsecondary · CVSS-BT (t0sche)
03

ssvc

A stakeholder decision — act, attend, or track — from exploitation and impact.

Exploitation: active · Automatable: yes · Technical Impact: totalcoordinatorcisa_ssvcUS
04

weaknesses

The CWE weakness classes this flaw belongs to.

05

exploits (5)

Public proof-of-concept and weaponised exploit code.

06

affected products (9)

Products and version ranges known to be affected.

07

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-21-077-03Hitachi ABB Power Grids eSOMS Telerik2021-03-18icsa · cisa_csaf_otUS

    Successful exploitation of these vulnerabilities could allow an attacker to upload malicious files to the server, discover sensitive information, or execute arbitrary code.

08

also known as (5)

Other names and identifiers for this entity.

09

sources

Which sources assert this record, and when.

11

references (15)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan