An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information that is sent in the POST request.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

No vendor fix yet; a mitigation is available.

  • MitigationLGatecisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationLGate 100cisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationLGate 101cisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationLGate 120cisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationLGate 320cisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationLGate 50cisa_csaf_ot

    Locus Energy has produced the following procedure to update LGate: 1. Cycle power to the LGate. This might require tripping one or more AC or DC breakers. 2. Power up the LGate and wait 5 minutes. 3. Use the web page on the LGate within the first half hour after power up to verify its firmware version. 3a. If connected to the local network, find the IP assigned to the LGate. Navigate to this IP using the browser on a computer also connected to the same subnet as the LGate. 3b. If the LGate is not connected to the local network, plug the Ethernet cable from the LGate into the computer. Wait until the computer settles into an AutoIP address in the 169.254.X.X range. Then use the IP 169.254.12.13 for the LGate. Use this IP in a browser to pull up the LGate web page. 4. The web page will display the model type, IP address, firmware version of the LGate (labeled as APP), and MAC address. Here is an example. In the picture below, the LGate (00:1E:C0:89:15:6E) is running 1.05C_EM3. 5. Verify that the firmware version is 1.05H_EM3 or above. 6. If the firmware version is less than 1.05H, send an email to (support@locusenergy.com) with the subject line: URGENT FW UPDATE REQUEST: MAC: <insert MAC address here> TO 1.05H or higher FW. 7. Locus Energy support will attempt to remotely update the firmware on the LGate and confirm via email. If they encounter any difficulty in updating the LGate, Locus Energy will contact the user to arrange alternate methods to update or replace the LGate. 8. If support confirms that the unit was updated to Version 1.05H or later, the user may repeat the above procedure (Steps 1-5) to verify this.

  • MitigationNovaWeb web HMIcisa_csaf_ot

    Sauter has not produced a mitigation for this vulnerability. This product was discontinued in 2013 and is no longer supported.

02

cvss

Technical severity, 0–10. One row per scoring source.

8.6
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USexploitability 10 · impact 6.4
v3.08.6highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:Lprimary · NVD / NIST USexploitability 3.9 · impact 4.7
v3.08.6highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:Lsecondary · CISA US
v3.07.9highCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (15)

Products and version ranges known to be affected.

05

advisories (2)

Vendor and ecosystem advisories describing this.

  • ICSA-16-231-01-0Locus Energy LGate Command Injection Vulnerability2016-05-22icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

  • ICSA-16-343-02Sauter NovaWeb Web HMI Authentication Bypass Vulnerability2016-09-11icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

06

also known as (3)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

published 2017-02-13modified 2026-06-17
09

references (10)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan