CVE-2016-10395
mediumpriority · track · 31EPSS 0.004 · 34 %ileEURUUSEPSS · scored 2026-10-27
In FlexNet Publisher versions before Luton SP1 (11.14.1.1) running FlexNet Publisher Licensing Service on Windows platform, a boundary error related to a named pipe within the FlexNet Publisher Licensing Service can be exploited to cause an out-of-bounds memory read access and subsequently execute arbitrary code with SYSTEM privileges.
remediations
Vendor fix, mitigation, or workaround guidance, as published by each source.
No vendor fix yet; a mitigation is available.
- MitigationCitectHistoriancisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationCitectSCADAcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Modicon Buildercisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Power Monitoring Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEcoStruxure Power SCADA Operationscisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationEnergy Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationPlantStruxure PEScisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationSCADA Expert Vijeo Citect / CitectSCADAcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationStruxureWare Power Monitoring Expertcisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership - MitigationVijeo Historian/CitectHistoriancisa_csaf_ot
Users using EcoStruxure Modicon Builder V3.0 are recommended to download and use the new version (V3.1)
https://partner.schneider-electric.com/partners/Menu/MyPartnership
cvss
Technical severity, 0–10. One row per scoring source.
base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 6.8–10
weaknesses
The CWE weakness classes this flaw belongs to.
affected products (25)
Products and version ranges known to be affected.
advisories (1)
Vendor and ecosystem advisories describing this.
- ICSA-18-144-01Schneider Electric Floating License Manager2018-05-24icsa · cisa_csaf_otUS
Successful exploitation of these vulnerabilities could cause a denial of service, allow arbitrary execution of code with system level privileges, or send users to arbitrary websites.
also known as (4)
Other names and identifiers for this entity.
sources
Which sources assert this record, and when.
references (14)
External citations — patches, advisories, analysis.
- https://secuniaresearch.flexerasoftware.com/advisories/76368/cnnvd
- https://www.flexerasoftware.com/Patchcnnvd
- https://ics-cert.us-cert.gov/advisories/ICSA-18-144-01enisa_euvd
- https://secuniaresearch.flexerasoftware.com/advisories/76368/enisa_euvd
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9134-vulnerabilities-within-schneider-electric-floating-license-managerenisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-046-01/enisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-137-01/enisa_euvd
- https://www.schneider-electric.com/en/download/document/SEVD-2018-144-01/enisa_euvd
Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.