CVE-2016-0701

lowpriority · track · 44EPSS 0.836 · 100 %ileDEEURUUS
grimoire priorityP1 · Urgent
Exploitable?
—
no known exploitation
Likely / severe?
83.6% (100th) EPSS
CVSS 2.6 · low
Is it mine?
23 products
Check your exposure
Who says so?
7 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-27

The DH_check_pub_key function in crypto/dh/dh_check.c in OpenSSL 1.0.2 before 1.0.2f does not ensure that prime numbers are appropriate for Diffie-Hellman (DH) key exchange, which makes it easier for remote attackers to discover a private DH exponent by making multiple handshakes with a peer that chose an inappropriate number, as demonstrated by a number in an X9.42 file.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

A vendor fix is available.

02

cvss

Technical severity, 0–10. One row per scoring source.

3.7
010

base score 0–10 · higher = more severe · hover a vector to decode

v2.02.6lowAV:N/AC:H/Au:N/C:P/I:N/A:Nprimary · NVD / NIST USexploitability 4.9 · impact 2.9
v3.03.7lowCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:Nprimary · NVD / NIST USexploitability 2.2 · impact 1.4
v2.02.6lowAV:N/AC:H/Au:N/C:P/I:N/A:Nsecondary · FSTEC (BDU) RU
v3.03.7lowCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:Hsecondary · CVSS-BT (t0sche)
v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:Csecondary · CISA US
v3.13.7lowCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:Csecondary · Siemens ProductCERT DE
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (23)

Products and version ranges known to be affected.

05

advisories (3)

Vendor and ecosystem advisories describing this.

  • SSA-412672SSA-412672: Multiple OpenSSL and OpenSSH Vulnerabilities in SCALANCE X-200RNA Switch Devices before V3.2.72022-12-13csaf · siemens_psirtDE

    SCALANCE X-200RNA switch devices before V3.2.7 contain multiple OpenSSL and OpenSSH vulnerabilities. The most severe of these vulnerabilities could allow a denial of service condition or could lead to execution of arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.

  • WID-SEC-W-2023-1594IBM Tivoli Network Manager: Mehrere SchwachstellenDeutsch2023-06-28csaf · cert_bundDE

    Ein entfernter, anonymer, authentisierter oder lokaler Angreifer kann mehrere Schwachstellen in IBM Tivoli Network Manager ausnutzen, um beliebigen Code auszuführen, Sicherheitsmaßnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand herbeizuführen, seine Privilegien auszuweiten, Daten zu manipulieren, nicht spezifizierte Auswirkungen zu verursachen und einen Cross-Site-Scripting-Angriff durchzuführen.

  • ICSA-22-349-21Siemens SCALANCE X-200RNA Switch Devices2022-12-13icsa · cisa_csaf_otUS

    SCALANCE X-200RNA switch devices before V3.2.7 contain multiple OpenSSL and OpenSSH vulnerabilities. The most severe of these vulnerabilities could allow a denial of service condition or could lead to execution of arbitrary code. Siemens has released updates for the affected products and recommends to update to the latest versions.

06

also known as (4)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (86)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan