CVE-2013-3957

highpriority · track · 31EPSS 0.018 · 78 %ileEURUUS
grimoire priorityP2 · Scheduled
Exploitable?
—
no known exploitation
Likely / severe?
1.78% (78th) EPSS
CVSS 7.5 · high
Is it mine?
12 products
Check your exposure
Who says so?
5 sources
cnnvd · enisa_euvd · fstec_bdu · cisa_csaf_ot

EPSS · scored 2026-10-24

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

01

remediations

Vendor fix, mitigation, or workaround guidance, as published by each source.

No vendor fix yet; a mitigation is available.

  • MitigationSIMATIC PCS7cisa_csaf_ot

    Siemens has produced a software update that resolves these vulnerabilities. The update can be applied to all versions of WinCC Web Navigator starting with Version 7.2. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.

  • MitigationWinCCcisa_csaf_ot

    Siemens has produced a software update that resolves these vulnerabilities. The update can be applied to all versions of WinCC Web Navigator starting with Version 7.2. Siemens recommends that asset owners and operators contact Siemens customer support to acquire the update.

02

cvss

Technical severity, 0–10. One row per scoring source.

10.0
010

base score 0–10 · higher = more severe · hover a vector to decode⚠ sources disagree · medium–critical · 6.4–10

v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Pprimary · NVD / NIST USexploitability 10 · impact 6.4
v2.07.5highAV:N/AC:L/Au:N/C:P/I:P/A:Psecondary · CISA US
v2.010criticalAV:N/AC:L/Au:N/C:C/I:C/A:Csecondary · FSTEC (BDU) RU
v2.06.4mediumAV:N/AC:L/Au:N/C:P/I:P/A:P/E:Usecondary · CVSS-BT (t0sche)
03

weaknesses

The CWE weakness classes this flaw belongs to.

04

affected products (12)

Products and version ranges known to be affected.

05

advisories (1)

Vendor and ecosystem advisories describing this.

  • ICSA-13-169-02Siemens WinCC 7.2 Multiple Vulnerabilities2013-03-21icsa · cisa_csaf_otUS

    This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov

06

also known as (6)

Other names and identifiers for this entity.

07

sources

Which sources assert this record, and when.

09

references (4)

External citations — patches, advisories, analysis.

scry

Attackers weaponise vulnerabilities like this against internet-exposed services. See what is exposed on your perimeter with a free passive scan.

Free scan